These are codes of the combustion engine controller (ECM), separate from the machine control codes. The manual gives the DTC number together with the SPN/FMI pair. Below are 276 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Genie Z-80/60, S-80 XC, S-85 XC, S-80 HF, S-85 HF, Z-34/22 IC, GS-2669 RT, GS-3369 RT, GS-4069 RT with GM engine. Source: Genie Service and Repair Manuals, GM engine code tables.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

All Genie codes: the list

CodeMeaningType
11Intake cam / distributor position errorblocking fault
16Crank and/or cam no sync during startblocking fault
24Exhaust cam position errorblocking fault
91FP low voltageblocking fault
92FP high voltageblocking fault
107MAP voltage lowblocking fault
108MAP pressure highblocking fault
111IAT higher than expected stage 1warning / function limited
112IAT voltage lowblocking fault
113IAT voltage highblocking fault
116ECT higher than expected stage 1warning / function limited
117ECT voltage lowblocking fault
118ECT voltage highblocking fault
121TPS1-2 lower than expectedblocking fault
122TPS1 voltage lowblocking fault
123TPS1 voltage highblocking fault
127IAT higher than expected stage 2blocking fault
129BP pressure lowwarning / function limited
134EGO1 open / lazywarning / function limited
140EGO3 open / lazywarning / function limited
154EGO2 open / lazywarning / function limited
160EGO4 open / lazywarning / function limited
171Adaptive-learn gasoline bank1 highwarning / function limited
172Adaptive-learn gasoline bank1 lowwarning / function limited
174Adaptive-learn gasoline bank2 highwarning / function limited
175Adaptive-learn gasoline bank2 lowwarning / function limited
182FT low voltageblocking fault
183FT high voltageblocking fault
187Gaseous fuel temp sender low voltageblocking fault
188Gaseous fuel temp sendr high voltageblocking fault
217ECT higher than expected stage 2blocking fault
219RPM higher than max allowed govern speedwarning / function limited
221TPS1-2 higher than expectedblocking fault
222TPS2 voltage lowblocking fault
223TPS2 voltage highblocking fault
234Boost control overboost failurewarning / function limited
236TIP activewarning / function limited
237TIP low voltageblocking fault
238TIP high voltageblocking fault
261Injector 1 open or short to groundblocking fault
262Injector 1 coil shortedblocking fault
264Injector 2 open or short to groundblocking fault
265Injector 2 coil shortedblocking fault
267Injector 3 open or short to groundblocking fault
268Injector 3 coil shortedblocking fault
270Injector 4 open or short to groundblocking fault
271Injector 4 coil shortedblocking fault
273Injector 5 open or short to groundblocking fault
274Injector 5 coil shortedblocking fault
276Injector 6 open or short to groundblocking fault
277Injector 6 coil shortedblocking fault
279Injector 7 open or short to groundblocking fault
280Injector 7 coil shortedblocking fault
282Injector 8 open or short to groundblocking fault
283Injector 8 coil shortedblocking fault
285Injector 9 open or short to groundblocking fault
308Cylinder 8 emissions/catalyst damaging fireblocking fault
326Knock1 excessive or erratic signalwarning / function limited
327Knock1 sensor open or not presentwarning / function limited
331Knock2 excessive or erratic signalwarning / function limited
332Knock2 sensor open or not presentwarning / function limited
336CRANK input signal noiseblocking fault
337Crank signal lossblocking fault
341CAM input signal noiseblocking fault
342Loss of CAM input signalblocking fault
359Fuel run-out longer than expectedwarning / function limited
420Catalyst inactive on gasoline (Bank 1)warning / function limited
430Catalyst inactive on gasoline (Bank 2)warning / function limited
502Roadspeed input loss of signalwarning / function limited
508IAC ground shortblocking fault
509IAC coil open/shortblocking fault
520Oil pressure sndr low prssure stage 1warning / function limited
521Oil pressure sender high pressurewarning / function limited
522Oil pressure sender low voltageblocking fault
523Oil pressure sender high voltageblocking fault
524Oil pressure lowblocking fault
562Vbat voltage lowwarning / function limited
563Vbat voltage highwarning / function limited
601Microprocessor failure - FLASHblocking fault
604Microprocessor failure - RAMblocking fault
606Microprocessor failure - COPblocking fault
615Start relay coil openblocking fault
616Start relay ground shortblocking fault
617Start relay coil short to powerblocking fault
627Fuel pump relay coil openblocking fault
628Fuel-pump high-side open or short to groundblocking fault
629Fuel-pump high-side short to powerblocking fault
642Sensor supply voltage 1 lowblocking fault
643Sensor supply voltage 1 highblocking fault
650MIL openwarning / function limited
652Sensor supply voltage 2 lowblocking fault
653Sensor supply voltage 2 highblocking fault
685Power relay coil openblocking fault
686Power relay ground shortblocking fault
687Power relay coil short to powerblocking fault
916Shift actuator feedback out-of-rangeblocking fault
919Shift unable to reach desired gearblocking fault
920Shift actuator or drive circuit failedblocking fault
1111RPM above fuel rev limit levelwarning / function limited
1112RPM above spark rev limit levelwarning / function limited
1121FPP1/2 simultaneous voltages out-of-rangeblocking fault
1122FPP1/2 do not match each other or IVSblocking fault
1131WGP voltage highblocking fault
1132WGP voltage lowblocking fault
1151Closed-loop LPG highwarning / function limited
1152Closed-loop LPG lowwarning / function limited
1153Closed-loop NG highwarning / function limited
1154Closed-loop NG lowwarning / function limited
1155Closed-loop gasoline bank1 highwarning / function limited
1156Closed-loop gasoline bank1 lowwarning / function limited
1157Closed-loop gasoline bank2 highwarning / function limited
1158Closed-loop gasoline bank2 lowwarning / function limited
1161Adaptive-learn LPG highwarning / function limited
1162Adaptive-learn LPG lowwarning / function limited
1163Adaptive-learn NG highwarning / function limited
1164Adaptive-learn NG lowwarning / function limited
1165Catalyst inactive on LPGwarning / function limited
1166Catalyst inactive on NGwarning / function limited
1171MegaJector delivery pressure higher than ectedwarning / function limited
1172MegaJector delivery pressure lower than ectedwarning / function limited
1173MegaJector comm lostblocking fault
1174MegaJector voltage supply highblocking fault
1175MegaJector voltage supply lowblocking fault
1176MegaJector internal actuator fault detectionblocking fault
1177MegaJector internal circuitry fault detectionblocking fault
1178MegaJector internal comm fault detectionblocking fault
1182Fuel impurity level highwarning / function limited
1183MegaJector autozero / lockoff failureblocking fault
1311Cylinder 1 misfire detectedwarning / function limited
1312Cylinder 2 misfire detectedwarning / function limited
1313Cylinder 3 misfire detectedwarning / function limited
1314Cylinder 4 misfire detectedwarning / function limited
1315Cylinder 5 misfire detectedwarning / function limited
1316Cylinder 6 misfire detectedwarning / function limited
1317Cylinder 7 misfire detectedwarning / function limited
1318Cylinder 8 misfire detectedwarning / function limited
1411EMWT1 voltage highblocking fault
1412EMWT2 voltage highblocking fault
1413EMWT1 voltage lowblocking fault
1414EMWT2 voltage lowblocking fault
1415EMWT1 higher than expected stage 1warning / function limited
1416EMWT2 higher than expected stage 1warning / function limited
1417EMWT1 higher than expected stage 2blocking fault
1418EMWT2 higher than expected stage 2blocking fault
1419ERWT1 voltage highblocking fault
1420ERWT2 voltage highblocking fault
1421ERWT1 voltage lowblocking fault
1422ERWT2 voltage lowblocking fault
1423ERWT1 higher than expected stage 1warning / function limited
1424ERWT2 higher than expected stage 1warning / function limited
1425ERWT1 higher than expected stage 2blocking fault
1426ERWT2 higher than expected stage 2blocking fault
1511AUX analog Pull-Up 1 high voltageblocking fault
1512AUX analog Pull-Up 1 low voltageblocking fault
1513AUX analog Pull-Up 2 high voltageblocking fault
1514AUX analog Pull-Up 2 low voltageblocking fault
1515AUX analog Pull-Down 1 high voltageblocking fault
1516AUX analog Pull-Down 1 low voltageeblocking fault
1517AUX analog Pull-Up 3 high voltageblocking fault
1518AUX analog Pull-Up 3 low voltageblocking fault
1521CHT higher than expected stage 1warning / function limited
1522CHT higher than expected stage 2blocking fault
1531Gov1/2/3 interlock failureblocking fault
1541AUX analog Pull-Up/Down 1 high voltageblocking fault
1542AUX analog Pull-Up/Down 1 low voltageblocking fault
1543AUX analog Pull-Up/Down 2 high voltageblocking fault
1544AUX analog Pull-Up/Down 2 low voltageblocking fault
1545AUX analog Pull-Up/Down 3 high voltageblocking fault
1546AUX analog Pull-Up/Down 3 low voltageblocking fault
1547AUX analog Pull-Up/Down 4 high voltageblocking fault
1548AUX analog Pull-Up/Down 4 low voltageblocking fault
1551AUX digital 1 high voltageblocking fault
1552AUX digital 1 low voltageblocking fault
1553AUX digital 2 high voltageblocking fault
1554AUX digital 2 low voltageblocking fault
1555AUX digital 3 high voltagewarning / function limited
1556AUX digital 3 low voltagewarning / function limited
1561AUX analog Pull-Down 2 high voltagewarning / function limited
1611Sensor supply voltage 1 and 2 out-of-rangeblocking fault
1612Microprocessor failure - RTI 1blocking fault
1613Microprocessor failure - RTI 2blocking fault
1614Microprocessor failure - RTI 3blocking fault
1615Microprocessor failure - A/Dblocking fault
1616Microprocessor failure - Interruptblocking fault
1621RS-485 Rx inactivewarning / function limited
1622RS-485 Rx noisewarning / function limited
1623RS-485 Rx bad packet formatwarning / function limited
1624RS-485 remote shutdown requestblocking fault
1625J1939 shutdown requestblocking fault
1626CAN-J1939 Tx faultblocking fault
1627CAN-J1939 Rx faultblocking fault
1628J1939 CAN address / engine-number flictblocking fault
1629J1939 TSC1 message receipt lossblocking fault
1630J1939 ETC message receipt losswarning / function limited
1632PWM1-Gauge1 short to powerwarning / function limited
1633PWM2-Gauge2 open / ground shortwarning / function limited
1634PWM2-Gauge2 short to powerwarning / function limited
1635PWM3-Gauge3 open / ground shortwarning / function limited
1636PWM3-Gauge3 short to powerwarning / function limited
1637PWM4 open / ground shortwarning / function limited
1638PWM4 short to powerwarning / function limited
1639PWM5 open / ground shortwarning / function limited
1640PWM5 short to powerwarning / function limited
1641Buzzer control ground shortwarning / function limited
1642Buzzer openwarning / function limited
1643Buzzer control short to powerwarning / function limited
1644MIL control ground shortwarning / function limited
1645MIL control short to powerwarning / function limited
1651J1939 ETC message receipt loss while in-gearblocking fault
1661PWM6 open / ground shortwarning / function limited
1662PWM6 short to powerwarning / function limited
1663PWM7 open / ground shortwarning / function limited
1664PWM7 short to powerwarning / function limited
1665PWM8 open / ground shortwarning / function limited
1666PWM8 short to powerwarning / function limited
1669PWM9 open / ground shortwarning / function limited
1670PWM9 short to powerwarning / function limited
2111Unable to reach lower TPSblocking fault
2112Unable to reach higher TPSblocking fault
2115FPP1 higher than IVSwarning / function limited
2116FPP2 higher than IVSwarning / function limited
2120FPP1 invalid voltage and FPP2 disagrees with IVSblocking fault
2121FPP1-2 lower than expectedwarning / function limited
2122FPP1 voltage highwarning / function limited
2123FPP1 voltage lowwarning / function limited
2125FPP2 invalid voltage and FPP1 disagrees with IVSblocking fault
2126FPP1-2 higher than expectedwarning / function limited
2127FPP2 voltage lowwarning / function limited
2128FPP2 voltage highwarning / function limited
2130IVS stuck at-idle, FPP1/2 matchwarning / function limited
2131IVS stuck off-idle, FPP1/2 matchwarning / function limited
2135TPS1/2 simultaneous voltages out-of-rangeblocking fault
2139FPP1 lower than IVSwarning / function limited
2140FPP2 lower than IVSwarning / function limited
2229BP pressure highwarning / function limited
2300Spark coil 1 primary open or short to groundblocking fault
2301Spark coil 1 primary shortedblocking fault
2303Spark coil 2 primary open or short to groundblocking fault
2304Spark coil 2 primary shortedblocking fault
2306Spark coil 3 primary open or short to groundblocking fault
2307Spark coil 3 primary shortedblocking fault
2309Spark coil 4 primary open or short to groundblocking fault
2310Spark coil 4 primary shortedblocking fault
2312Spark coil 5 primary open or short to groundblocking fault
2313Spark coil 5 primary shortedblocking fault
2315Spark coil 6 primary open or short to groundblocking fault
2316Spark coil 6 primary shortedblocking fault
2318Spark coil 7 primary open or short to groundblocking fault
2319Spark coil 7 primary shortedblocking fault
2321Spark coil 8 primary open or short to groundblocking fault
2322Spark coil 8 primary shortedblocking fault
2324Spark coil 9 primary open or short to groundblocking fault
2325Spark coil 9 primary shortedblocking fault
2327Spark coil 10 primary open or short to undblocking fault
2328Spark coil 10 primary shortedblocking fault
2428EGT temperature highwarning / function limited
2618Tach output ground shortwarning / function limited
2619Tach output short to powerwarning / function limited
8901UEGO microprocessor internal faultwarning / function limited
8902UEGO heater supply high voltagewarning / function limited
8903UEGO heater supply low voltagewarning / function limited
8904UEGO cal resistor voltage highwarning / function limited
8905UEGO cal resistor voltage lowwarning / function limited
8906UEGO return voltage shorted highwarning / function limited
8907UEGO return voltage shorted lowwarning / function limited
8908UEGO pump voltage shorted highwarning / function limited
8909UEGO pump voltage shorted lowwarning / function limited
8910UEGO sense cell voltage highwarning / function limited
8911UEGO sense cell voltage lowwarning / function limited
8912UEGO pump voltage at high drive limiwarning / function limited
8913UEGO pump voltage at low drive limitwarning / function limited
8914UEGO sense cell slow to warm upwarning / function limited
8915UEGO pump cell slow to warm upwarning / function limited
8916UEGO sense cell impedance highwarning / function limited
8917UEGO pump cell impedance highwarning / function limited
8918UEGO pump cell impedance lowwarning / function limited