609 609 105609 609 104

Haulotte HA20 RTJ, HA20 RTJ O, HA20 RTJ PRO (HA61 RTJ)

Haulotte error code F06.03 — Gauges out of Range

Message on the display: Gauges out of Range

Code F06.03 occurs in machines: Haulotte HA20RTJ, HA20RTJ O, HA20RTJ PRO, HA61RTJ O, HA61RTJ PRO.

blocking fault

[case 1] Gauges out of range (load management system activated). VAR[GaugesOutOfRange]=1 Check SP800 connections to ground, to U104 ECU analogue inputs. [case 2] Gauges out of range (load management system activated).

Description from the Haulotte service manual, in the original wording.

Effect on the machine: --> SP800 Not in [1500; 20500]µA. --> SP801 Not in [1500; 20500]µA.

Possible causes

  • Check SP801 connections to ground, to U104 ECU analogue inputs.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: Haulotte Maintenance Book HA20 RTJ (4001055090), fault codes chapter.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.