609 609 105609 609 104

Haulotte HA26 RTJ O, HA26 RTJ PRO (HA80 RTJ)

Haulotte error code F06.03 — Gauges out of Range

Message on the display: Gauges out of Range

Code F06.03 occurs in machines: Haulotte HA26 RTJ O, HA26 RTJ O SW, HA26 RTJ PRO, HA26 RTJ PRO SW.

blocking fault

Gauges out of range (load management system activated). —> SP800 not in [1500; 20500] µA

Description from the Haulotte service manual, in the original wording.

Possible causes

  • Check SP800 connections to ground, to U104 ECU analogue inputs Gauges out of range (load management system activated). —> SP801 not in [1500; 20500] µA
  • Check SP801 connections to ground, to U104 ECU analogue inputs

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: Haulotte Maintenance Book HA26 RTJ (4001055180), fault codes chapter.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code F06.03 not go away?

RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Haulotte service · Haulotte parts · All Haulotte codes of this system

Neighbouring Haulotte codes