609 609 105609 609 104

Haulotte HA26 RTJ O, HA26 RTJ PRO (HA80 RTJ)

Haulotte error code F07.11 — Telescope length

Message on the display: Telescope length

Code F07.11 occurs in machines: Haulotte HA26 RTJ O, HA26 RTJ O SW, HA26 RTJ PRO, HA26 RTJ PRO SW.

blocking fault

General check on angle position can be done as following : Telescope retracted, horizontal boom Extend the boom (nearly 1m) Extend the boom (nearly 8m) Extend the boom (nearly 8m+) Extend the boom (nearly 8m++) Extend the boom to high end Retract the boom (nearly 8m++) Retract the boom (nearly 8m+) Retract the boom (nearly 8m) Retract the boom (nearly 1m) Telescope retracted, boom down To erase F07.11 failure: retract the boom telescope then descent arm and boom, check the position detectors (repair if one is broken), power OFF the machine and then power ON If failure is still active then one of the six detectors defining the machine position is not in the expected state [case 1] Voltage failure of SQ533 sensor [case 2] Incoherence between telescope position sensors : Falling edge on telescope extended sensor out of the allowed zone (telescope limit not detected) [case 4] Incoherence between telescope position sensors : Raising edge on telescope extended sensor out of the allowed zone (telescope limit not detected) [case 8] Incoherence between telescope position sensors : Raising edge on telescope limit detector not in allowed zone (telescope extended sensor) during telescope extend movement [case 16] Incoherence between telescope position sensors : Falling edge on telescope limit detector not in allowed zone (telescope extended sensor) during telescope extend movement [case 32] Incoherence between telescope limit detector and telescope retracted position detectors [case 64] Incoherence between telescope extended detector and telescope retracted position detectors

Description from the Haulotte service manual, in the original wording.

Effect on the machine: --> SQ523 > 6.00V --> SQ533=↓ & SQ532=OFF --> SQ533=↓ & SQ532=OFF --> SQ533=OFF & SQ532=↑ --> SQ533=ON & SQ532=↓ -->SQ532=ON & SQ530=ON & SQ531=ON --> SQ533=OFF & SQ530=ON & SQ531=ON

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: Haulotte Maintenance Book HA26 RTJ (4001055180), fault codes chapter.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code F07.11 not go away?

RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Haulotte service · Haulotte parts · All Haulotte codes of this system