Haulotte HT43 RTJ PRO (HT132 RTJ PRO)
Haulotte error code F04.10 — Drive
Message on the display: Drive
Code F04.10 occurs in machines: Haulotte HT43RTJ PRO, HT132RTJ PRO.
blocking fault
[case 1] Failure is detected on proportional electro valve (forward drive) [case 2] Failure is detected on proportional electro valve (reverse drive)
Description from the Haulotte service manual, in the original wording.
Effect on the machine: --> YV160F=FAIL --> YV160B=FAIL
Possible causes
- Check connection to +12V (12V201)
- Check connection to U104 ECU (31.2)
- Check connection to U104 ECU (54.2)
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Check connection to +12V (12V201) Check connection to U104 ECU (31.2) Check connection to +12V (12V201) Check connection to U104 ECU (54.2)
Source: Haulotte Maintenance Book HT43 RTJ PRO (4001034910), fault codes chapter.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code F04.10 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system