| FUNCTION SELECTED BUT TRIGGER SWITCH OPEN | FUNCTION SELECTED BUT TRIGGER SWITCH OPEN | warning / function limited |
| RUNNING AT CUTBACK - ABOVE ELEVATION | RUNNING AT CUTBACK - ABOVE ELEVATION | message |
| ACCESSORY FAULT | ACCESSORY FAULT | warning / function limited |
| FRONT LEFT LEVELING JACK AT END OF STROKE | FRONT LEFT LEVELING JACK AT END OF STROKE | message |
| FRONT RIGHT LEVELING JACK AT END OF STROKE | FRONT RIGHT LEVELING JACK AT END OF STROKE | message |
| REAR LEFT LEVELING JACK AT END OF STROKE | REAR LEFT LEVELING JACK AT END OF STROKE | message |
| REAR RIGHT LEVELING JACK AT END OF STROKE | REAR RIGHT LEVELING JACK AT END OF STROKE | message |
| LEVELING JACK SET PREVENTED - ECM LOST | LEVELING JACK SET PREVENTED - ECM LOST | blocking fault |
| GENERATOR PREVENTED - ECM LOST | GENERATOR PREVENTED - ECM LOST | blocking fault |
| DRIVE PREVENTED - ECM LOST | DRIVE PREVENTED - ECM LOST | blocking fault |
| ELEVATION SENSOR DISAGREEMENT | ELEVATION SENSOR DISAGREEMENT | blocking fault |
| KEYSWITCH FAULTY - PLATFORM & GROUND ACTIVE TOGETHERflash code 2/1 | KEYSWITCH FAULTY - PLATFORM & GROUND ACTIVE TOGETHER | warning / function limited |
| TRIGGER SWITCH WIRING SHORTED HIGH IN PLATFORM CABLEflash code 2/2 | TRIGGER SWITCH WIRING SHORTED HIGH IN PLATFORM CABLE | blocking fault |
| TRIGGER SWITCH WIRING SHORTED LOW IN PLATFORM CABLEflash code 2/2 | TRIGGER SWITCH WIRING SHORTED LOW IN PLATFORM CABLE | blocking fault |
| FUNCTION LOCKED OUT - DRIVE SELECT PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - DRIVE SELECT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - LIFT SELECT PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - LIFT SELECT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - FRONT DECK SELECT PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - FRONT DECK SELECT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - REAR DECK SELECT PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - REAR DECK SELECT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - START PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - START PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - STEER LEFT PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - STEER LEFT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - STEER RIGHT PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - STEER RIGHT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - AUX POWER SWITCH PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - AUX POWER SWITCH PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GENERATOR SWITCH PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - GENERATOR SWITCH PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - AUTOLEVEL SWITCH PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - AUTOLEVEL SWITCH PERMANENTLY CLOSED | blocking fault |
| TRIGGER CLOSED TOO LONG WHILE IN NEUTRALflash code 2/2 | TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL | warning / function limited |
| FUNCTION LOCKED OUT - JOYSTICK NOT CENTEREDflash code 2/2 | FUNCTION LOCKED OUT - JOYSTICK NOT CENTERED | warning / function limited |
| FUNCTION LOCKED OUT - TRIGGER SWITCH PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - TRIGGER SWITCH PERMANENTLY CLOSED | blocking fault |
| JOYSTICK FAULTY - STEER SWITCHES ACTIVE TOGETHERflash code 2/2 | JOYSTICK FAULTY - STEER SWITCHES ACTIVE TOGETHER | blocking fault |
| FUNCTION LOCKED OUT - HORN SWITCH PERMANENTLY CLOSEDflash code 2/2 | FUNCTION LOCKED OUT - HORN SWITCH PERMANENTLY CLOSED | blocking fault |
| JOYSTICK CALIBRATION FAULTYflash code 2/2 | JOYSTICK CALIBRATION FAULTY | blocking fault |
| FUNCTION LOCKED OUT - GROUND LIFT UP PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND LIFT UP PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GROUND LIFT DOWN PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND LIFT DOWN PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GROUND FRONT DECK EXT PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND FRONT DECK EXT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GROUND FRONT DECK RET PREMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND FRONT DECK RET PREMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GROUND REAR DECK EXT PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND REAR DECK EXT PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GROUND REAR DECK RET PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND REAR DECK RET PERMANENTLY CLOSED | blocking fault |
| GROUND LIFT UP/DOWN ACTIVE TOGETHERflash code 2/3 | GROUND LIFT UP/DOWN ACTIVE TOGETHER | warning / function limited |
| GROUND FRONT DECK EXTEND/RETRACT ACTIVE TOGETHERflash code 2/3 | GROUND FRONT DECK EXTEND/RETRACT ACTIVE TOGETHER | warning / function limited |
| GROUND REAR DECK EXTEND/RETRACT ACTIVE TOGETHERflash code 2/3 | GROUND REAR DECK EXTEND/RETRACT ACTIVE TOGETHER | warning / function limited |
| NO SIGNAL FROM TILT SENSOR X AXIS - CHECK WIRINGflash code 2/3 | NO SIGNAL FROM TILT SENSOR X AXIS - CHECK WIRING | blocking fault |
| NO SIGNAL FROM TILT SENSOR Y AXIS - CHECK WIRINGflash code 2/3 | NO SIGNAL FROM TILT SENSOR Y AXIS - CHECK WIRING | blocking fault |
| LEVEL SENSOR FAILUREflash code 2/3 | LEVEL SENSOR FAILURE | blocking fault |
| FUNCTION LOCKED OUT - GROUND AUX SWITCH PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND AUX SWITCH PERMANENTLY CLOSED | blocking fault |
| FUNCTION LOCKED OUT - GROUND START SWITCH PERMANENTLY CLOSEDflash code 2/3 | FUNCTION LOCKED OUT - GROUND START SWITCH PERMANENTLY CLOSED | blocking fault |
| ELEV ANGLE SENSOR FAULTY - NOT MOUNTED OR VOLTAGE OUT OF RANGEflash code 2/5 | ELEV ANGLE SENSOR FAULTY - NOT MOUNTED OR VOLTAGE OUT OF RANGE | blocking fault |
| ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATEDflash code 2/5 | ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATED | blocking fault |
| ELEVATION PROX SWITCH PERMANENTLY CLOSEDflash code 2/5 | ELEVATION PROX SWITCH PERMANENTLY CLOSED | blocking fault |
| ELEVATION PROX SWITCH PERMANENTLY OPENflash code 2/5 | ELEVATION PROX SWITCH PERMANENTLY OPEN | blocking fault |
| FRONT LEFT LEVELING JACK PRESSURE TRANSDUCER FAILUREflash code 2/5 | FRONT LEFT LEVELING JACK PRESSURE TRANSDUCER FAILURE | blocking fault |
| FRONT RIGHT LEVELING JACK PRESSURE TRANSDUCER FAILUREflash code 2/5 | FRONT RIGHT LEVELING JACK PRESSURE TRANSDUCER FAILURE | blocking fault |
| REAR LEFT LEVELING JACK PRESSURE TRANSDUCER FAILUREflash code 2/5 | REAR LEFT LEVELING JACK PRESSURE TRANSDUCER FAILURE | blocking fault |
| REAR RIGHT LEVELING JACK PRESSURE TRANSDUCER FAILUREflash code 2/5 | REAR RIGHT LEVELING JACK PRESSURE TRANSDUCER FAILURE | blocking fault |
| PLATFORM OVERLOADflash code 2/5 | PLATFORM OVERLOAD | blocking fault |
| FRONT LEFT LEVELING JACK STOW SWITCH PERMANENTLY CLOSEDflash code 2/5 | FRONT LEFT LEVELING JACK STOW SWITCH PERMANENTLY CLOSED | blocking fault |
| FRONT RIGHT LEVELING JACK STOW SWITCH PERMANENTLY CLOSEDflash code 2/5 | FRONT RIGHT LEVELING JACK STOW SWITCH PERMANENTLY CLOSED | blocking fault |
| REAR LEFT LEVELING JACK STOW SWITCH PERMANENTLY CLOSEDflash code 2/5 | REAR LEFT LEVELING JACK STOW SWITCH PERMANENTLY CLOSED | blocking fault |
| REAR RIGHT LEVELING JACK STOW SWITCH PERMANENTLY CLOSEDflash code 2/5 | REAR RIGHT LEVELING JACK STOW SWITCH PERMANENTLY CLOSED | blocking fault |
| ELEV ANGLE SENSOR NOT DETECTING CHANGEflash code 2/5 | ELEV ANGLE SENSOR NOT DETECTING CHANGE | blocking fault |
| FRONT LEFT LEVELING JACK OPEN CIRCUITflash code 2/6 | FRONT LEFT LEVELING JACK OPEN CIRCUIT | blocking fault |
| FRONT LEFT LEVELING JACK SHORT TO GROUNDflash code 2/6 | FRONT LEFT LEVELING JACK SHORT TO GROUND | blocking fault |
| FRONT LEFT LEVELING JACK SHORT TO BATTERYflash code 2/6 | FRONT LEFT LEVELING JACK SHORT TO BATTERY | blocking fault |
| FRONT RIGHT LEVELING JACK OPEN CIRCUITflash code 2/6 | FRONT RIGHT LEVELING JACK OPEN CIRCUIT | blocking fault |
| FRONT RIGHT LEVELING JACK SHORT TO GROUNDflash code 2/6 | FRONT RIGHT LEVELING JACK SHORT TO GROUND | blocking fault |
| FRONT RIGHT LEVELING JACK SHORT TO BATTERYflash code 2/6 | FRONT RIGHT LEVELING JACK SHORT TO BATTERY | blocking fault |
| REAR LEFT LEVELING JACK OPEN CIRCUITflash code 2/6 | REAR LEFT LEVELING JACK OPEN CIRCUIT | blocking fault |
| REAR LEFT LEVELING JACK SHORT TO GROUNDflash code 2/6 | REAR LEFT LEVELING JACK SHORT TO GROUND | blocking fault |
| REAR LEFT LEVELING JACK SHORT TO BATTERYflash code 2/6 | REAR LEFT LEVELING JACK SHORT TO BATTERY | blocking fault |
| REAR RIGHT LEVELING JACK OPEN CIRCUITflash code 2/6 | REAR RIGHT LEVELING JACK OPEN CIRCUIT | blocking fault |
| REAR RIGHT LEVELING JACK SHORT TO GROUNDflash code 2/6 | REAR RIGHT LEVELING JACK SHORT TO GROUND | blocking fault |
| REAR RIGHT LEVELING JACK SHORT TO BATTERYflash code 2/6 | REAR RIGHT LEVELING JACK SHORT TO BATTERY | blocking fault |
| LEVELING JACK EXTEND VALVE OPEN CIRCUITflash code 2/6 | LEVELING JACK EXTEND VALVE OPEN CIRCUIT | blocking fault |
| LEVELING JACK EXTEND VALVE SHORT TO GROUNDflash code 2/6 | LEVELING JACK EXTEND VALVE SHORT TO GROUND | blocking fault |
| LEVELING JACK EXTEND VALVE SHORT TO BATTERYflash code 2/6 | LEVELING JACK EXTEND VALVE SHORT TO BATTERY | blocking fault |
| LEVELING JACK RETRACT VALVE OPEN CIRCUITflash code 2/6 | LEVELING JACK RETRACT VALVE OPEN CIRCUIT | blocking fault |
| LEVELING JACK RETRACT VALVE SHORT TO GROUNDflash code 2/6 | LEVELING JACK RETRACT VALVE SHORT TO GROUND | blocking fault |
| LEVELING JACK RETRACT VALVE SHORT TO BATTERYflash code 2/6 | LEVELING JACK RETRACT VALVE SHORT TO BATTERY | blocking fault |
| FRONT DECK EXTEND VALVE OPEN CIRCUITflash code 2/6 | FRONT DECK EXTEND VALVE OPEN CIRCUIT | blocking fault |
| FRONT DECK EXTEND VALVE SHORT TO GROUNDflash code 2/6 | FRONT DECK EXTEND VALVE SHORT TO GROUND | blocking fault |
| FRONT DECK EXTEND VALVE SHORT TO BATTERYflash code 2/6 | FRONT DECK EXTEND VALVE SHORT TO BATTERY | blocking fault |
| FRONT DECK RETRACT VALVE OPEN CIRCUITflash code 2/6 | FRONT DECK RETRACT VALVE OPEN CIRCUIT | blocking fault |
| FRONT DECK RETRACT VALVE SHORT TO GROUNDflash code 2/6 | FRONT DECK RETRACT VALVE SHORT TO GROUND | blocking fault |
| FRONT DECK RETRACT VALVE SHORT TO BATTERYflash code 2/6 | FRONT DECK RETRACT VALVE SHORT TO BATTERY | blocking fault |
| REAR DECK EXTEND VALVE OPEN CIRCUITflash code 2/6 | REAR DECK EXTEND VALVE OPEN CIRCUIT | blocking fault |
| REAR DECK EXTEND VALVE SHORT TO GROUNDflash code 2/6 | REAR DECK EXTEND VALVE SHORT TO GROUND | blocking fault |
| REAR DECK EXTEND VALVE SHORT TO BATTERYflash code 2/6 | REAR DECK EXTEND VALVE SHORT TO BATTERY | blocking fault |
| REAR DECK RETRACT VALVE OPEN CIRCUITflash code 2/6 | REAR DECK RETRACT VALVE OPEN CIRCUIT | blocking fault |
| REAR DECK RETRACT VALVE SHORT TO GROUNDflash code 2/6 | REAR DECK RETRACT VALVE SHORT TO GROUND | blocking fault |
| REAR DECK RETRACT VALVE SHORT TO BATTERYflash code 2/6 | REAR DECK RETRACT VALVE SHORT TO BATTERY | blocking fault |
| FUEL SENSOR SHORT TO BATTERYflash code 4/3 | FUEL SENSOR SHORT TO BATTERY | blocking fault |
| FUEL SENSOR SHORT TO GROUNDflash code 4/3 | FUEL SENSOR SHORT TO GROUND | blocking fault |
| FUEL SENSOR DISCONNECTEDflash code 4/3 | FUEL SENSOR DISCONNECTED | blocking fault |
| OIL PRESSURE SHORT TO BATTERYflash code 4/3 | OIL PRESSURE SHORT TO BATTERY | blocking fault |
| OIL PRESSURE SHORT TO GROUNDflash code 4/3 | OIL PRESSURE SHORT TO GROUND | blocking fault |
| COOLANT TEMPERATURE SHORT TO GROUNDflash code 4/3 | COOLANT TEMPERATURE SHORT TO GROUND | blocking fault |
| ENGINE TEMPERATURE HIGHflash code 4/3 | ENGINE TEMPERATURE HIGH | message |
| AIR FILTER BYPASSEDflash code 4/3 | AIR FILTER BYPASSED | message |
| NO ALTERNATOR OUTPUTflash code 4/3 | NO ALTERNATOR OUTPUT | blocking fault |
| OIL PRESSURE LOWflash code 4/3 | OIL PRESSURE LOW | blocking fault |
| ENGINE SHUTDOWN COMMANDED - CHECK ENGINE SENSORSflash code 4/3 | ENGINE SHUTDOWN COMMANDED - CHECK ENGINE SENSORS | blocking fault |
| WRONG ENGINE SELECTEDflash code 4/3 | WRONG ENGINE SELECTED | blocking fault |
| DEUTZ ECM FAULT CODEflash code 4/3 | DEUTZ ECM FAULT CODE | blocking fault |
| BATTERY LOWflash code 4/4 | BATTERY LOW | warning / function limited |
| BATTERY TOO HIGH - SYSTEM SHUTDOWNflash code 4/4 | BATTERY TOO HIGH - SYSTEM SHUTDOWN | blocking fault |
| BATTERY TOO LOW - SYSTEM SHUTDOWNflash code 4/4 | BATTERY TOO LOW - SYSTEM SHUTDOWN | blocking fault |
| LSS BATTERY VOLTAGE HIGHflash code 4/4 | LSS BATTERY VOLTAGE HIGH | warning / function limited |
| LSS BATTERY VOLTAGE LOWflash code 4/4 | LSS BATTERY VOLTAGE LOW | warning / function limited |
| SPEED SENSOR READING INVALID SPEEDflash code 5/5 | SPEED SENSOR READING INVALID SPEED | blocking fault |
| SPEED INPUT LOSTflash code 5/5 | SPEED INPUT LOST | blocking fault |
| CAN BUS FAILUREflash code 6/6 | CAN BUS FAILURE | blocking fault |
| LSS NOT SENDING CAN MESSAGESflash code 6/6 | LSS NOT SENDING CAN MESSAGES | blocking fault |
| ENGINE CONTROLLER CAN COMMUNICATION LOSTflash code 6/6 | ENGINE CONTROLLER CAN COMMUNICATION LOST | blocking fault |
| TWO PLATFORM MODULES DETECTEDflash code 6/6 | TWO PLATFORM MODULES DETECTED | blocking fault |
| LSS CELL #1 ERRORflash code 8/1 | LSS CELL #1 ERROR | blocking fault |
| LSS CELL #2 ERRORflash code 8/2 | LSS CELL #2 ERROR | blocking fault |
| LSS CELL #3 ERRORflash code 8/3 | LSS CELL #3 ERROR | blocking fault |
| LSS CELL #4 ERRORflash code 8/4 | LSS CELL #4 ERROR | blocking fault |
| LSS WATCHDOG RESETflash code 9/1 | LSS WATCHDOG RESET | blocking fault |
| LSS EEPROM ERRORflash code 9/2 | LSS EEPROM ERROR | blocking fault |
| LSS HAS NOT BEEN CALIBRATEDflash code 9/3 | LSS HAS NOT BEEN CALIBRATED | blocking fault |
| LSS NEEDS TO BE RE-CALIBRATEDflash code 9/9 | LSS NEEDS TO BE RE-CALIBRATED | blocking fault |
| LSS INTERNAL ERROR - PIN EXCITATIONflash code 9/9 | LSS INTERNAL ERROR - PIN EXCITATION | blocking fault |
| LSS INTERNAL ERROR - DRIVER FAULTflash code 9/9 | LSS INTERNAL ERROR - DRIVER FAULT | blocking fault |
| LSS INTERNAL ERROR - DRDY MISSING FROM A/Dflash code 9/9 | LSS INTERNAL ERROR - DRDY MISSING FROM A/D | blocking fault |
| EEPROM FAILURE - CHECK ALL SETTINGSflash code 9/9 | EEPROM FAILURE - CHECK ALL SETTINGS | blocking fault |