609 609 105609 609 104

Zoomlion ZS1530E and ZS1930E scissor lifts

Zoomlion error code 05 — Hardware Internal Fault

Message on the display: Hardware Internal Fault

Code 05 occurs in machines: Zoomlion ZS1530E, ZS1930E.

blocking fault

The Zoomlion display shows code 05 with the message “Hardware Internal Fault”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Disable Lifting and Driving

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Hardware Internal Fault: ECU may be malfunctioning, replace it.

Source: Zoomlion Service and Maintenance Manual (global.zoomlion-access.com), ZS1530E / ZS1930E, fault code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 05 not go away?

RK Rental services Zoomlion lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Zoomlion service · Spare parts · All Zoomlion codes of this system

Neighbouring Zoomlion codes