609 609 105609 609 104

Zoomlion ZS2023ERT electric rough terrain scissor lift

Zoomlion error code C1 — Discharge Temp Fault 1

Message on the display: Discharge Temp Fault 1

Code C1 occurs in machines: Zoomlion ZS2023ERT.

warning / function limited

Discharging temperature fault level 1

Description from the Zoomlion service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

If the temperature is too high, please let the machine sit for a while. If the temperature is too low, please use it after charging and heating. If the temperature is normal, please contact the service personnel.

Source: Zoomlion Service and Maintenance Manual (global.zoomlion-access.com), ZS2023ERT, fault code and troubleshooting table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code C1 not go away?

RK Rental services Zoomlion lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Zoomlion service · Spare parts · All Zoomlion codes of this system