609 609 105609 609 104

Genie S-85 XC FE / E: traction battery charger

Genie error code E-0-0-104 — J1772 Can Message Comm Never Received

Message on the display: J1772 Can Message Comm Never Received

Code E-0-0-104 occurs in machines: Genie S-85 XC FE, S-85 XC E.

blocking fault

Genie fault ID 135, type 8.

Description from the Genie service manual, in the original wording.

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

An expected J1772 related message (i.e., with a receive timeout; e.g., RPDO or PGN) has not been received, but an EVSE is connected and otherwise charger is ready to enable AC.. Check CAN cabling. Ensure MCUs/BMS configured to send expected messages.

Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), charger code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code E-0-0-104 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system