Genie S-85 XC FE / E: traction battery charger
Genie error code E-0-0-9 — Battery Temp Changing Too Quick
Message on the display: Battery Temp Changing Too Quick
Code E-0-0-9 occurs in machines: Genie S-85 XC FE, S-85 XC E.
warning / function limited
Genie fault ID 233, type 9.
Description from the Genie service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Check loose/corrosion on output cable or bad configuration if the battery temperature sensor is used for charge control.
Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), charger code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code E-0-0-9 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system