Genie battery charger (GS, GR, GRC, QS)

Genie error code F-0-0-5 — Output relay voltage too high when closed.

Message on the display: Output relay voltage too high when closed.

Code F-0-0-5 occurs in machines: Genie GR-12, GR-15, GR-20, GRC-12, QS-12R, QS-15R, QS-20R, QS-12W, QS-15W, QS-20W, GS-1330m, GS-1432m, GS-1932m, GS-1530, GS-1532, GS-1930, GS-1932, GS-2032, GS-2632, GS-3232, GS-2046, GS-2646, GS-3246, GS-4046, GS-4655.

blocking fault

The Genie display shows code F-0-0-5 with the message “Output relay voltage too high when closed”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Possible causes

  • Internal charger fault.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Disconnect AC input and battery pack for 30 seconds. If fault does not clear, contact Genie Product Support.

Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1403004, 1321209, 1307550, 1314708, 1275811, 1309020), charger code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code F-0-0-5 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes