The code is made up of two two-digit numbers: the source of the error (red LED) and the error type (yellow LED) on the ALC-500 controller board in the platform control box; the LEDs flash out the first and the second number in turn. Two short alarm beeps on the platform every 30 seconds indicate a stored error. In our database 21-11 means source 21, type 11. Reading the code requires opening the control box, so it is done by service. Below are 81 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Genie S-40, S-45, S-80, S-85, Z-60/34, Z-51/30J. Source: Genie Service Manual S-80/S-85 (111165), S-40/S-45 (102521), Z-60/34 and Service and Repair Manual Z-51/30J (1268553GT), Control System Fault Codes tables.

Showing the first 30: type more digits of the code.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

All Genie codes: the list

CodeMeaningType
21-11Boom 1 Joystick (primary boom up/down) — Value at 5Vblocking fault
21-12Boom 1 Joystick (primary boom up/down) — Value too highblocking fault
21-15Boom 1 Joystick (primary boom up/down) — Value too lowblocking fault
21-16Boom 1 Joystick (primary boom up/down) — Value at 0Vblocking fault
21-17Boom 1 Joystick (primary boom up/down) — Not calibratedblocking fault
21-18Boom 1 Joystick (primary boom up/down) — Just calibratedmessage
22-21Boom 1 directional valves — Faultblocking fault
23-12Boom 1 flow control valve — Value too highblocking fault
23-15Boom 1 flow control valve — Value too lowblocking fault
23-17Boom 1 flow control valve — Not calibratedwarning / function limited
23-18Boom 1 flow control valve — Just calibratedmessage
24-11Boom 1 angle sensor — Value at 5Vwarning / function limited
24-12Boom 1 angle sensor — Value too highwarning / function limited
24-15Boom 1 angle sensor — Value too lowwarning / function limited
24-16Boom 1 angle sensor — Value at 0Vwarning / function limited
24-17Boom 1 angle sensor — Not calibratedwarning / function limited
24-31Boom 1 angle sensor — Invalid setupwarning / function limited
26-19Angle sensor cross check — Out of rangewarning / function limited
31-11Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value at 5Vblocking fault
31-12Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value too highblocking fault
31-15Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value too lowblocking fault
31-16Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value at 0Vblocking fault
31-17Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Not calibratedblocking fault
31-18Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Just calibratedmessage
32-21Boom 2 directional valves — Faultblocking fault
33-12Boom 2 flow control valve — Value too highblocking fault
33-15Boom 2 flow control valve — Value too lowblocking fault
33-17Boom 2 flow control valve — Not calibratedwarning / function limited
33-18Boom 2 flow control valve — Just calibratedmessage
34-31Ext./Ret. limit switch — Invalid setupwarning / function limited
41-11Turntable rotate joystick — Value at 5Vblocking fault
41-12Turntable rotate joystick — Value too highblocking fault
41-15Turntable rotate joystick — Value too lowblocking fault
41-16Turntable rotate joystick — Value at 0Vblocking fault
41-17Turntable rotate joystick — Not calibratedblocking fault
41-18Turntable rotate joystick — Just calibratedmessage
42-21Turntable rotate directional valves — Faultblocking fault
43-12Turntable rotate flow control valve — Value too highblocking fault
43-15Turntable rotate flow control valve — Value too lowblocking fault
43-17Turntable rotate flow control valve — Not calibratedwarning / function limited
43-18Turntable rotate flow control valve — Just calibratedmessage
44-21Drive enable override switches — Faultblocking fault
45-21Platform level switch — Faultblocking fault
46-21Primary extend/retract switch — Faultblocking fault
51-11Drive joystick — Value at 5Vblocking fault
51-12Drive joystick — Value too highblocking fault
51-15Drive joystick — Value too lowblocking fault
51-16Drive joystick — Value at 0Vblocking fault
51-17Drive joystick — Not calibratedblocking fault
51-18Drive joystick — Just calibratedmessage
53-12Drive flow valve (EDC) — Value too highblocking fault
53-15Drive flow valve (EDC) — Value too lowblocking fault
53-17Drive flow valve (EDC) — Not calibratedwarning / function limited
53-18Drive flow valve (EDC) — Just calibratedmessage
54-21Drive brake valve — Faultblocking fault
55-21High speed drive motor Valve — Faultwarning / function limited
56-21Platform level valve — Faultblocking fault
57-12Foot switch / ECU power crosscheck — Value too highblocking fault
57-15Foot switch / ECU power crosscheck — Value too lowblocking fault
61-11Steer joystick — Value at 5Vblocking fault
61-12Steer joystick — Value too highblocking fault
61-15Steer joystick — Value too lowblocking fault
61-16Steer joystick — Value at 0Vblocking fault
61-17Steer joystick — Not calibratedblocking fault
61-18Steer joystick — Just calibratedmessage
62-21Steer directional valves — Faultblocking fault
34-36Ext. Ret. Limit Switch — Cross check faultblocking fault
42-17Turntable Rotate Directional Valves — Not calibratedwarning / function limited
75-12SCON — Value Too Highwarning / function limited
75-13SCON — No Responseblocking fault
75-15SCON — Value Too Lowblocking fault
75-34SCON — Software mismatchblocking fault
76-17Platform load cell overloaded — Not calibratedblocking fault
76-21Platform load cell overloaded — Internal load cell statusblocking fault
76-31Platform load cell overloaded — Invalid setupblocking fault
76-36Platform load cell overloaded — Cross check faultblocking fault
79-13Hour meter — No Responsewarning / function limited
81-21Platform Load — Faultwarning / function limited
82-12Overload recovery cutout relay — Value Too Highblocking fault
82-15Overload recovery cutout relay — Value Too Lowblocking fault
82-21Overload recovery cutout relay — Faultblocking fault