Genie error codes
Genie S and Z boom lifts: ‘source + error type’ codes (S-40, S-45, S-80, S-85, Z-60/34, Z-51/30J)
The code is made up of two two-digit numbers: the source of the error (red LED) and the error type (yellow LED) on the ALC-500 controller board in the platform control box; the LEDs flash out the first and the second number in turn. Two short alarm beeps on the platform every 30 seconds indicate a stored error. In our database 21-11 means source 21, type 11. Reading the code requires opening the control box, so it is done by service. Below are 81 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Genie S-40, S-45, S-80, S-85, Z-60/34, Z-51/30J. Source: Genie Service Manual S-80/S-85 (111165), S-40/S-45 (102521), Z-60/34 and Service and Repair Manual Z-51/30J (1268553GT), Control System Fault Codes tables.
- 21-11Boom 1 Joystick (primary boom up/down) — Value at 5V
- 21-12Boom 1 Joystick (primary boom up/down) — Value too high
- 21-15Boom 1 Joystick (primary boom up/down) — Value too low
- 21-16Boom 1 Joystick (primary boom up/down) — Value at 0V
- 21-17Boom 1 Joystick (primary boom up/down) — Not calibrated
- 21-18Boom 1 Joystick (primary boom up/down) — Just calibrated
- 22-21Boom 1 directional valves — Fault
- 23-12Boom 1 flow control valve — Value too high
- 23-15Boom 1 flow control valve — Value too low
- 23-17Boom 1 flow control valve — Not calibrated
- 23-18Boom 1 flow control valve — Just calibrated
- 24-11Boom 1 angle sensor — Value at 5V
- 24-12Boom 1 angle sensor — Value too high
- 24-15Boom 1 angle sensor — Value too low
- 24-16Boom 1 angle sensor — Value at 0V
- 24-17Boom 1 angle sensor — Not calibrated
- 24-31Boom 1 angle sensor — Invalid setup
- 26-19Angle sensor cross check — Out of range
- 31-11Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value at 5V
- 31-12Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value too high
- 31-15Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value too low
- 31-16Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Value at 0V
- 31-17Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Not calibrated
- 31-18Boom 2 Joystick (secondary boom up/down or primary boom extend/retract) — Just calibrated
- 32-21Boom 2 directional valves — Fault
- 33-12Boom 2 flow control valve — Value too high
- 33-15Boom 2 flow control valve — Value too low
- 33-17Boom 2 flow control valve — Not calibrated
- 33-18Boom 2 flow control valve — Just calibrated
- 34-31Ext./Ret. limit switch — Invalid setup
Showing the first 30: type more digits of the code.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.