Genie Z-80/60, Z-135/70, S-100, S-105, S-120, S-125: faults by source and type
Genie message — JIB ROTATE CW/CCW FLOW VALVE(S) — JUST CALIBRATED
This message occurs in machines: Genie SX-180, SX-150, SX-135 XC.
message
The Genie display shows this message as “JIB ROTATE CW/CCW FLOW VALVE(S) — JUST CALIBRATED”. It is an information message and does not need any reaction.
Effect on the machine: Initiate one second beep of audible warning device
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Self-clearing (transient)
Source: Genie Service Manual Z-80/60 (88619), Service and Repair Manuals Z-135/70 (1268557) and S-100/S-105/S-120/S-125 (102916), Control System Fault Codes tables.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does the message not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie messages of this system
Neighbouring Genie messages
- PRIMARY BOOM UP/DOWN FLOW VALVE(S) (#1 AND #2) — VALUE TOO HIGH
- PRIMARY BOOM UP/DOWN FLOW VALVE(S) (#1 AND #2) — VALUE TOO LOW
- JIB ROTATE CW/CCW FLOW VALVE(S) — NOT CALIBRATED
- JIB ROTATE CW/CCW FLOW VALVE(S) — VALUE TOO HIGH
- JIB ROTATE CW/CCW FLOW VALVE(S) — VALUE TOO LOW
- PLATFORM ROTATE SWITCHES — FAULT CHECK (BOTH BUTTONS PRESSED)