609 609 105609 609 104

Genie error codes

Genie with Deutz D436 engine: engine controller codes

These are codes of the combustion engine controller (ECM), separate from the machine control codes. The code has the form SPN-FMI (e.g. 84-8). Below are 19 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Genie S-60 XC, S-60 with Deutz engine. Source: Genie Service and Repair Manual S-60 XC, Deutz engine code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

All Genie codes: the list

CodeMeaningType
84-8Speed sensor: no tach; harnessblocking fault
91-2Set point sensor 1: short circuit; harnessblocking fault
91-11Error Hand Setp1: Contact Genie product support.blocking fault
100-1Oil pressure warning: oil pressure below speed / Oil pressure switch: pressure below switch off limitblocking fault
100-2Oil pressure: short circuit; harnessblocking fault
102-2Charge air pressure: short circuit; harnessblocking fault
105-0Charge air temp: warning: exceeded warning level / Charge air temp. switch: exceeded switch off limitblocking fault
105-2Charge air temp: short circuit; harnessblocking fault
108-12Atmospheric pressure: Out of range. Program logic Parameter fault: No data found or checksum data faulty. Stack overflow: Internal calculation fault. Internal fault: Contact Genie product support.blocking fault
110-0Coolant temperature warning: exceeded warning level / Coolant temperature switch: exceeded switch off limitblocking fault
110-2Coolant temp: short circuit; harnessblocking fault
111-1Coolant level warning: switch input "Low coolant level" is activeblocking fault
171-12Internal temperature: Control unit internal temperature out of range.warning / function limited
174-0Fuel temperature warning: exceeded levelwarning / function limited
174-2Fuel temp: short circuit; harness Functional fault warningblocking fault
190-0Excess speed switch-off: speed i excess of limit Sensorsblocking fault
190-8Speed sensor 1: sensor fault; distance from gear; harness / Speed sensor 2: sensor fault; distance from gear; harnessblocking fault
201-2Set point sensor 2: short circuit; harnessblocking fault
898-2Error CAN setp1: Contact Genie product support.blocking fault