Genie GR-20J and GR-26J (vertical mast lifts with jib)
Genie error code 01-19 — Controller interface board — Serial error #1
Message on the display: Controller interface board — Serial error #1
Code 01-19 occurs in machines: Genie GR-20J, GR-26J.
blocking fault
The controller has not responded to the request from the base board as expected.
Description from the Genie service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Replace the controller.
Source: Genie Service and Repair Manual GR-20J / GR-26J (Part No. 227656, 1312899), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 01-19 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system