Genie GS scissor lifts with SmartLink control (GS-1930, GS-1932, GS-2632, GS-3246, GS-4047, GS-4655)
Genie error code C043 — DCON LR ECM FAULT TYPE 07
Message on the display: DCON LR ECM FAULT TYPE 07
Code C043 occurs in machines: Genie GS-2669 BE, GS-3369 BE, GS-4069 BE, GS-2669 DC, GS-3369 DC, GS-4069 DC.
blocking fault
Open circuit of the key switch circuit or battery positive/negative of the left rear drive controller.
Description from the Genie service manual, in the original wording.
Effect on the machine: All functions inhibited.
Possible causes
- Open circuit of the left rear motor controller harness.
- Open circuit to B+ and/or B-.
- Key switch relay CR61 not closed.
- Left rear DCON or GCON ECM.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
What service does
A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.
Source: Genie Service and Repair Manual GS-30/32/46/47 (Part No. 1272217GT), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code C043 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system