609 609 105609 609 104

Genie GS scissor lifts with SmartLink control (GS-1930, GS-1932, GS-2632, GS-3246, GS-4047, GS-4655)

Genie error code H086 — COILFAULT OSC RIGHT:Open

Message on the display: COILFAULT OSC RIGHT:Open

Code H086 occurs in machines: Genie GS-2669 BE, GS-3369 BE, GS-4069 BE, GS-2669 DC, GS-3369 DC, GS-4069 DC.

blocking fault

Open circuit of the oscillate right circuit.

Description from the Genie service manual, in the original wording.

Effect on the machine: All functions inhibited except platform as long as machine is in the elevated position. If machine is in stowed position, all functionality is resumed.

Possible causes

  • Open circuit in oscillate right harness.
  • Oscillate right coil open circuit.
  • GCON ECM.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

What service does

A qualified service technician reads the code with the manufacturer's diagnostic tools, finds the cause, clears the code and carries out a function test.

Source: Genie Service and Repair Manual GS-30/32/46/47 (Part No. 1272217GT), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.