Genie error codes
Genie GS: lithium battery (codes F0–F15)
A code F0–F15 is reported by the lithium battery management system (BMS). Below are 16 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Genie GS-1332m, GS-1432m, GS-1932m, GS-1932, GS-2632, GS-3232, GS-2646, GS-3246, GS-4046, GS-4655 with lithium battery. Source: Genie Service and Repair Manuals (Part No. 1321209, 1403004), lithium battery code table.
- F0Over temperature (cells)
- F1Over temperature (BMS)
- F2Under temperature (charge)
- F3Over current (recoverable)
- F4Over current (permanent fault)
- F5Short circuit
- F6Cell under voltage during discharge only
- F7Cell over voltage during charge only (primary)
- F8Cell over voltage during charge only (secondary)
- F9Safety under voltage
- F10Cell pre-charge fault
- F11Charge fault
- F12Under temperature (discharge)
- F13Miscellaneous fault
- F14Pre-discharge
- F15Permanent fault
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
All Genie codes: the list
| Code | Meaning | Type |
|---|---|---|
| F0 | Over temperature (cells) | blocking fault |
| F1 | Over temperature (BMS) | blocking fault |
| F2 | Under temperature (charge) | blocking fault |
| F3 | Over current (recoverable) | warning / function limited |
| F4 | Over current (permanent fault) | blocking fault |
| F5 | Short circuit | blocking fault |
| F6 | Cell under voltage during discharge only | blocking fault |
| F7 | Cell over voltage during charge only (primary) | warning / function limited |
| F8 | Cell over voltage during charge only (secondary) | blocking fault |
| F9 | Safety under voltage | blocking fault |
| F10 | Cell pre-charge fault | warning / function limited |
| F11 | Charge fault | warning / function limited |
| F12 | Under temperature (discharge) | blocking fault |
| F13 | Miscellaneous fault | blocking fault |
| F14 | Pre-discharge | blocking fault |
| F15 | Permanent fault | blocking fault |