Genie with Perkins 854F engine: engine controller codes
Genie error code 1221-14 — Continuously Monitored Systems Support/Status : Special Instruction
Message on the display: Continuously Monitored Systems Support/Status : Special Instruction
Code 1221-14 occurs in machines: Genie SX-180, SX-150, ZX-135/70, SX-105 XC, SX-135 XC.
warning / function limited
SPN 1221, FMI 14.
Description from the Genie service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Refer to engine manual: Another diagnostic code has requested engine speed limitation. The warning lamp will flash.The engine speed is limited to 1200rpm. Troubleshoot all other diagnostic codes.No troubleshooting is required for this diagnostic code.
Source: Genie Service and Repair Manuals, Perkins 854F engine code tables.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 1221-14 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 1209-3Engine Exhaust Gas Pressure :Voltage Above Normal
- 1209-4Engine Exhaust Gas Pressure :Voltage Below Normal
- 1221-2Continuously Monitored Systems Support/Status ;Erratic,Intermittent,or Incorrect
- 1239-0Engine Fuel Leakage 1 :High- most severe (3)
- 1485-7ECM Main Relay :Not Responding Properly
- 1485-14ECM Main Relay :Special Instruction