Genie with Perkins 854F engine: engine controller codes
Genie error code 3219-17 — After treatment #1 Intake Gas Sensor at Temperature : Low - least severe (1)
Message on the display: After treatment #1 Intake Gas Sensor at Temperature : Low - least severe (1)
Code 3219-17 occurs in machines: Genie SX-180, SX-150, ZX-135/70, SX-105 XC, SX-135 XC.
warning / function limited
SPN 3219, FMI 17.
Description from the Genie service manual, in the original wording.
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Refer to engine manual: Oxygen Level- Test
Source: Genie Service and Repair Manuals, Perkins 854F engine code tables.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 3219-17 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 3217-13After treatment #1 Intake 02 : Out of Calibration
- 3217-15After treatment #1 Intake 02 : High - least severe (1)
- 3219-15After treatment #1 Intake Gas Sensor at Temperature : High- least severe (1)
- 3222-3After treatment #1 Intake Gas Sensor Heater : Voltage Above Normal
- 3222-4After treatment #1 Intake Gas Sensor Heater :Voltage Below Normal
- 3222-5After treatment #1 Intake Gas Sensor Heater :Current Below Normal