609 609 105609 609 104

Older Genie S-100, S-105, S-120, S-125: display messages

Genie message — BLUE END YELLOW SIDE STEER VALVE FAULT

This message occurs in machines: Genie S-100, S-105, S-120, S-125.

blocking fault

The Genie display shows this message as “BLUE END YELLOW SIDE STEER VALVE FAULT”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Blue end yellow side CW or blue end yellow side CCW functions inoperative.

Possible causes

  • Blue end yellow side CW or CCW valve coils circuits open or shorted to ground or the coils are bad.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Refer to charts 36 to troubleshoot.

Source: Genie Service Manual S-100 / S-105 / S-120 / S-125 (Part No. 62401), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does the message not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie messages of this system