Older Genie S-100, S-105, S-120, S-125: display messages
Genie message — PLATFORM LEVEL SENSOR DEGREES VALUE TOO LOW
This message occurs in machines: Genie S-100, S-105, S-120, S-125.
blocking fault
The Genie display shows this message as “PLATFORM LEVEL SENSOR DEGREES VALUE TOO LOW”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: Platform level and boom up/down functions inoperative.
Possible causes
- Damaged circuit between platform level sensor and platform control box or platform level sensor may need to be replaced.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Refer to chart 24 to troubleshoot.
Source: Genie Service Manual S-100 / S-105 / S-120 / S-125 (Part No. 62401), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does the message not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie messages of this system