609 609 105609 609 104

Older Genie S-100, S-105, S-120, S-125: display messages

Genie message — YELLOW END BLUE SIDE STEER SENSOR VALUE TOO LOW

This message occurs in machines: Genie S-100, S-105, S-120, S-125.

blocking fault

The Genie display shows this message as “YELLOW END BLUE SIDE STEER SENSOR VALUE TOO LOW”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Yellow end blue side steering functions inoperative.

Possible causes

  • Damaged circuit between yellow end blue side steering sensor and DCON box or steering sensor may need to be replaced.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Refer to chart 37 to troubleshoot.

Source: Genie Service Manual S-100 / S-105 / S-120 / S-125 (Part No. 62401), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does the message not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie messages of this system