Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)
Haulotte error code F04.04 — Output in open or short circuit : ON/OFF valve for arm lift YV5A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for arm descent YV5B is defective (or missing) or wire is cut
Message on the display: Output in open or short circuit : ON/OFF valve for arm lift YV5A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for arm descent YV5B is defective (or missing) or wire is cut
Code F04.04 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.
blocking fault
Output in open or short circuit : ON/OFF valve for arm lift YV5A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for arm descent YV5B is defective (or missing) or wire is cut
Description from the Haulotte service manual, in the original wording.
Possible causes
- Change coil YV5A, check wire 220 between loom bloc + turret box or wire 203 on coil itself (+12V)
- Change coil YV5B, check wire 221 between loom bloc + turret box or wire 203 on coil itself (+12V)
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Change coil YV5A, check wire 220 between loom bloc + turret box or wire 203 on coil itself (+12V) • Change coil YV5B, check wire 221 between loom bloc + turret box or wire 203 on coil itself (+12V)
Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code F04.04 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system
Neighbouring Haulotte codes
- F04.01Output in open or short circuit : ON/OFF valve for left steering YV2A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for right steering YA2B is defective (or missing) or wire is cut
- F04.02Output in open or short circuit : ON/OFF valve for basket compensation lifting YV3A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for basket compensation descent YV3B is defective (or missing) or wire is cut
- F04.03Output in open or short circuit : ON/OFF valve for turntable left rotation YV4A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for turntable right rotation YV4B is defective (or missing) or wire is cut
- F04.05Output in open or short circuit : ON/OFF valve for boom lift YV6A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for boom descent YV6B is defective (or missing) or wire is cut
- F04.06Output in open or short circuit : ON/OFF valve for right steering YV7A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for left steering YV7B is defective (or missing) or wire is cut
- F04.07Output in open or short circuit : ON/OFF valve for jib lifting YV8A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for jib descent YV8B is defective (or missing) or wire is cut