The machine's display shows a code made of letters (e.g. AV, SC, EV, OL, SE, MX, EP); the manual assigns them Fxx.yy codes, under which they are listed in our database. The original code from the display is given in the description. Below are 40 codes with the original message from the manufacturer's manual and its description. They apply to these machines: Haulotte HA12 CJ, HA12 CJ+, HA32 CJ, HA32 CJ+. Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.

Showing the first 30: type more digits of the code.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

All Haulotte codes: the list

CodeMeaningType
F01.01Problems in stator/rotor current, logic, hardware, current probes, or CAN bus network or problems linked to an over or low voltageblocking fault
F01.03Problems in main contactor KMG or with the contactor for selection traction/pump KM1 (Open circuit, contact stuck or short-circuit)blocking fault
F01.05Lack of power or problem in the outputs motors/pumpblocking fault
F01.06Speed variator unit in thermal securitywarning / function limited
F01.07Wrong sequence for starting or error on one speed variator unit inputwarning / function limited
F01.08Problem on batteries or batteries too weakwarning / function limited
F02.01Output in open or short circuit : Pump power coil contactor KM2 is defective (or missing) or wire is cutblocking fault
F02.02Output in open or short circuit : Emergency pump power coil contactor KMS is defective (or missing) or wire is cut (Fault visible only if the Enable Switch SA10b is activated)blocking fault
F03.03Output in open or short circuit : Validation relay KAV is defective (or missing) or wire is cutblocking fault
F03.04Output in open or short circuit : Brakes release relay KAB is defective (or missing) or wire is cut (Fault only with SEVCON speed unit)blocking fault
F03.05Output in open or short circuit : Flashing light relay KAF is defective (or missing) or wire is cutblocking fault
F03.06Output in open or short circuit : Horn relay KAK is defective (or missing) or wire is cutblocking fault
F04.01Output in open or short circuit : ON/OFF valve for left steering YV2A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for right steering YA2B is defective (or missing) or wire is cutblocking fault
F04.02Output in open or short circuit : ON/OFF valve for basket compensation lifting YV3A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for basket compensation descent YV3B is defective (or missing) or wire is cutblocking fault
F04.03Output in open or short circuit : ON/OFF valve for turntable left rotation YV4A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for turntable right rotation YV4B is defective (or missing) or wire is cutblocking fault
F04.04Output in open or short circuit : ON/OFF valve for arm lift YV5A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for arm descent YV5B is defective (or missing) or wire is cutblocking fault
F04.05Output in open or short circuit : ON/OFF valve for boom lift YV6A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for boom descent YV6B is defective (or missing) or wire is cutblocking fault
F04.06Output in open or short circuit : ON/OFF valve for right steering YV7A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for left steering YV7B is defective (or missing) or wire is cutblocking fault
F04.07Output in open or short circuit : ON/OFF valve for jib lifting YV8A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for jib descent YV8B is defective (or missing) or wire is cutblocking fault
F04.08Output in open or short circuit : ON/OFF valve for basket rotation left side YV9A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for basket rotation right side YV9B is defective (or missing) or wire is cutblocking fault
F04.09Output in open or short circuit : ON/OFF valve for jib rotation left side YV10A is defective (or missing) or wire is cut Output in open or short circuit : ON/OFF valve for jib rotation right side YV10B is defective (or missing) or wire is cut Joysticks (controllers)-toggle switchesblocking fault
F04.11Output in open or short circuit : PWM valve for main movements YV1 is defective (or missing) or wire is cutblocking fault
F04.12Output in open or short circuit : PWM valve for secondary movements YV0 is defective (or missing) or wire is cutblocking fault
F05.01Signal out of range or inconsistent neutral value on drive joystickblocking fault
F05.04Signal out of range or inconsistent neutral value on rotation /lift joystickblocking fault
F05.06Signal out of range or inconsistent neutral value on rotation /lift joystickblocking fault
F06.01Adress fault on slave module doing the load function Inconsistant values between EEPROM datas saved between module master B2 and slave B3 / Fault in Jib learning Cal 1blocking fault
F06.02Inconsistent values for the calculation of the pressure recorded between modules node B2 master and slave B3 / Inconsistent values for the calculation of the pressure reference between modules node B2 master and node B3 slaveblocking fault
F07.01Incoherent status of sensors : No change during movementblocking fault
F07.20Fault in G1 pressure sensor in jib cylinder Pressure variation too important in the jib small chamberblocking fault
F07.21Fault in G2 pressure sensor in jib cylinder Pressure variation too important in the jib large chamberblocking fault
F07.22Inconsistent values between jib movement and jib angle measurement Fault in A1 relative angle sensorblocking fault
F07.23Inconsistent value between compensation movement and jib angle Fault in A2 absolute angle sensor (Inclinometer)blocking fault
F12.01CAN fault communicationblocking fault
F12.02EEPROM CHECK-SUM errorblocking fault
F13.01Inconsistent value or neutral position not OK when power is ON, on one of the toggle switch in lower control boxwarning / function limited
F13.02Inconsistent value or neutral position not OK when power is ON, on one of the toggle switch in upper control boxwarning / function limited
OL09Resultant pressure out of rangeblocking fault
SE02Anti by-pass safety : Detection of SQ34 from 0 to 1 without any movementblocking fault
SE03E-stop safety : Detection position before power OFF and check position when power is ON again (Sensor state should not have changed)blocking fault