Haulotte HA12 CJ and HA12 CJ+ (HA32 CJ)
Haulotte error code OL09 — Resultant pressure out of range
Message on the display: Resultant pressure out of range
Code OL09 occurs in machines: Haulotte HA12CJ, HA32CJ, HA12CJ+, HA32CJ+.
blocking fault
Resultant pressure out of range
Description from the Haulotte service manual, in the original wording.
Possible causes
- Pressure registered in node B2 out of range compared to the threshold value(Low and high)
- The fault appears if the difference between the registered value and the recordered value is above 2 seconds
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Pressure registered in node B2 out of range compared to the threshold value(Low and high) • The fault appears if the difference between the registered value and the recordered value is above 2 seconds
Source: Haulotte Maintenance Book HA12 CJ (4000786480), fault code table.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code OL09 not go away?
RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Haulotte service · Haulotte parts · All Haulotte codes of this system
Neighbouring Haulotte codes
- F12.02EEPROM CHECK-SUM error
- F13.01Inconsistent value or neutral position not OK when power is ON, on one of the toggle switch in lower control box
- F13.02Inconsistent value or neutral position not OK when power is ON, on one of the toggle switch in upper control box
- SE02Anti by-pass safety : Detection of SQ34 from 0 to 1 without any movement
- SE03E-stop safety : Detection position before power OFF and check position when power is ON again (Sensor state should not have changed)