609 609 105609 609 104

Haulotte HA20 LE and HA20 LE PRO (HA61 LE): electric boom lift

Haulotte error code F06.03 — Gauges out of Range

Message on the display: Gauges out of Range

Code F06.03 occurs in machines: Haulotte HA20LE, HA61LE, HA20LE PRO, HA61LE PRO.

blocking fault

[case 1] b0 Gauge out of range(load management system activated) : --> SP800 Not in [1500; 20500] µA [case 2] b1 Gauge out of range(load management system activated) : --> SP801 Not in [1500; 20500] µA

Description from the Haulotte service manual, in the original wording.

Possible causes

  • Check SP800 connections to ground
  • Check connections to U104 ECU analogue inputs
  • Check SP801 connections to ground

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Check SP800 connections to ground Check connections to U104 ECU analogue inputs Check SP801 connections to ground Check connections to U104 ECU analogue inputs

Source: Haulotte Maintenance Book HA20 LE (4001028020), fault codes chapter.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code F06.03 not go away?

RK Rental services Haulotte lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Haulotte service · Haulotte parts · All Haulotte codes of this system

Neighbouring Haulotte codes