609 609 105609 609 104

Zoomlion ZS1218ERT electric rough terrain scissor lift

Zoomlion error code 32 — Angle Sensor Fault

Message on the display: Angle Sensor Fault

Code 32 occurs in machines: Zoomlion ZS1218ERT.

blocking fault

The Zoomlion display shows code 32 with the message “Angle Sensor Fault”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Only able to descend

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Angle Sensor Fault: Check the wiring to the sensor and then the sensor itself. Also check to make sure that the correct option is properly selected (or not) for load sensing.

Source: Zoomlion Service and Maintenance Manual (global.zoomlion-access.com), ZS1218ERT, fault code table.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 32 not go away?

RK Rental services Zoomlion lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Zoomlion service · Spare parts · All Zoomlion codes of this system

Neighbouring Zoomlion codes