Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 135-54 — Wall Powered Charger Fault Codes — The charger has been unable to calibrate the current offset.
Message on the display: Wall Powered Charger Fault Codes — The charger has been unable to calibrate the current offset.
Code 135-54 occurs in machines: Genie S-60 DC, Z-45 DC, Z-45 FE.
blocking fault
The Genie display shows code 135-54 with the message “Wall Powered Charger Fault Codes — The charger has been unable to calibrate the current offset”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: Charger configuration not possible
Possible causes
The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Remove AC and battery for minimum 30 seconds and retry charger
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 135-54 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 135-51Wall Powered Charger Fault Codes — DC-DC failure: LLC excessive leakage fault
- 135-52Wall Powered Charger Fault Codes — PFC failure: PFC excessive leakage fault
- 135-53Wall Powered Charger Fault Codes — PFC has taken too long to boost
- 135-55Wall Powered Charger Fault Codes — The output relay voltage too high when relay is closed.
- 136-0Pump [ECON] — No Response
- 136-08Pump / Generator Motor Controller — Component fault