| 15-21 | Foot Switch — Fault | blocking fault |
| 15-28 | Foot Switch — Timeout | blocking fault |
| 16-12 | Speed Adjustment Dial — VALUE TO HIGH | warning / function limited |
| 16-27 | Speed Adjustmen T Toggle Switch — Active at startup | warning / function limited |
| 17-25 | AUX PUMP _ Auxiliary Pump — RESISTANCE TOO HIGH | blocking fault |
| 17-26 | AUX PUMP _ Auxiliary Pump — RESISTANCE TOO LOW | blocking fault |
| 18-12 | Proportional Relief Valve — VALUE TOO HIGH | warning / function limited |
| 18-16 | Proportional Relief Valve — VALUE AT 0V | blocking fault |
| 18-21 | Proportion Al Relief Valve — Fault | warning / function limited |
| 19-27 | Aux Pump Toggle Switch — Active at startup | blocking fault |
| 20-11 | Primary Extend/Retract Joystick Rocker — Shorted to supply | blocking fault |
| 20-16 | Primary Extend/Retract Joystick Rocker — Sensor at Zero | blocking fault |
| 20-17 | Primary Extend/Retract Joystick Rocker — Not calibrated | blocking fault |
| 21-11 | Primary Up/Down Joystick — Shorted to Supply | blocking fault |
| 21-16 | Primary Up/Down Joystick — Value at 0 V | blocking fault |
| 21-17 | Primary Up/Down Joystick — Not Calibrate d | blocking fault |
| 22-25 | Primary Up Valve — Value too high | blocking fault |
| 22-26 | Primary Up Valve — Value too low | blocking fault |
| 23-25 | Primary Down Valve — Value too high | blocking fault |
| 23-26 | Primary Down Valve — Value too low | blocking fault |
| 24-11 | Primary Boom Angle Sensor — Shorted to Supply | blocking fault |
| 24-16 | Primary Boom Angle Sensor — Value at 0 V | blocking fault |
| 24-17 | Primary Boom Angle Sensor — Not Calibrated | blocking fault |
| 24-19 | Primary Boom Angle Sensor — Out of Range | blocking fault |
| 26-25 | Primary Extend Valve — Value too high | blocking fault |
| 26-26 | Primary Extend Valve — Value too low | blocking fault |
| 27-25 | Primary Retract Valve — Value too high | blocking fault |
| 27-26 | Primary Retract Valve — Value too low | blocking fault |
| 31-11 | Secondary Up/Down Joystick — Shorted to Supply | blocking fault |
| 31-16 | Secondary Up/Down Joystick — Value at 0 V | blocking fault |
| 31-17 | Secondary Up/Down Joystick — Not Calibrated | blocking fault |
| 32-25 | Secondary Up Valve — Value too high | blocking fault |
| 32-26 | Secondary Up Valve — Value too low | blocking fault |
| 33-25 | Secondary Down Valve — Value too high | blocking fault |
| 33-26 | Secondary Down Valve — Value too low | blocking fault |
| 36-25 | Jib Up/Platform Rotate Left Valve — Value too high | blocking fault |
| 36-26 | Jib Up/Platform Rotate Left Valve — Value too low | blocking fault |
| 37-25 | Jib Down/Platfor M Rotate Right Valve — Value too high | blocking fault |
| 37-26 | Jib Down/Platfor M Rotate Right Valve — Value too low | blocking fault |
| 40-25 | Jib Select Valve — Value too high | blocking fault |
| 40-26 | Jib Select Valve — Value too low | blocking fault |
| 41-11 | Turntable Joystick — Shorted to Supply | blocking fault |
| 41-16 | Turntable Joystick — Value at 0 V | blocking fault |
| 41-17 | Turntable Joystick — Not Calibrated | blocking fault |
| 42-25 | Turntable Cw Valve — Value too high | blocking fault |
| 42-26 | Turntable Cw Valve — Value too low | blocking fault |
| 43-25 | Turntable Ccw Valve — Value too high | blocking fault |
| 43-26 | Turntable Ccw Valve — Value too low | blocking fault |
| 44-27 | Drive Enable Toggle Switch — Active at startup | blocking fault |
| 48-25 | Small Pump Enable Valve — Value too high | blocking fault |
| 48-26 | Small Pump Enable Valve — Value too low | blocking fault |
| 49-25 | Large Pump Enable Valve — Value too high | blocking fault |
| 49-26 | Large Pump Enable Valve — Value too low | blocking fault |
| 51-11 | Drive Joystick — Shorted to Supply | blocking fault |
| 51-16 | Drive Joystick — Value at 0 V | blocking fault |
| 51-17 | Drive Joystick — Not Calibrated | blocking fault |
| 56-13 | Telematics Device — Not Detected | warning / function limited |
| 59-0 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — No Response | blocking fault |
| 59-12 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Controller Overcurrent | blocking fault |
| 59-13 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Current Sensor Fault | blocking fault |
| 59-14 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Precharge Failed | blocking fault |
| 59-15 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Controller Severe Undertemp | blocking fault |
| 59-16 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Controller Severe Overtemp | blocking fault |
| 59-17 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Severe B+ Undervoltage | warning / function limited |
| 59-18 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Severe B+ Overvoltage | blocking fault |
| 59-22 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Controller Overtemp Cutback | warning / function limited |
| 59-23 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — B+ Undervoltage Cutback | warning / function limited |
| 59-24 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — B+ Overvoltage Cutback | warning / function limited |
| 59-25 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — +5V Supply Failure | warning / function limited |
| 59-26 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Digital Out 6 Overcurrent | warning / function limited |
| 59-27 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Digital Out 7 Overcurrent | warning / function limited |
| 59-28 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Motor Temp Hot Cutback | warning / function limited |
| 59-29 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Motor Temp Sensor Fault | warning / function limited |
| 59-31 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Coil1 Driver Open Short | warning / function limited |
| 59-32 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Coil2 Driver Open/Short | warning / function limited |
| 59-33 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Coil3Driver Open/Short | warning / function limited |
| 59-34 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — Coil4Driver Open/Short | warning / function limited |
| 59-35 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same fault codes — PD Open/Short | warning / function limited |
| 59-36 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Encoder Fault | warning / function limited |
| 59-37 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Motor Open | blocking fault |
| 59-38 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Main Contactor Welded | blocking fault |
| 59-39 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Main Contactor Did Not Close | blocking fault |
| 59-46 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — EEPROM Failure | blocking fault |
| 59-47 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — HPD/Sequencing Fault | warning / function limited |
| 59-49 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Parameter Change Fault | blocking fault |
| 59-68 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — VCL Runtime Error | blocking fault |
| 59-69 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — External Supply Out of Range | warning / function limited |
| 59-71 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — OS General | blocking fault |
| 59-72 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — PDO Timeout | warning / function limited |
| 59-73 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Stall Detected | warning / function limited |
| 59-77 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Supervisor Fault | blocking fault |
| 59-78 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Supervisor Incompatible | blocking fault |
| 59-82 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Bad Calibrations | blocking fault |
| 59-83 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Driver Supply Fault | blocking fault |
| 59-84 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Following Error Fault | blocking fault |
| 59-87 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Motor Characterization Fault | blocking fault |
| 59-88 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Encoder Steps Count Fault | blocking fault |
| 59-89 | Right Rear Drive Controller Note: Left Rear, Left Front, Right Front, Drive [DCON], and Pump [ECON] motor controllers all have the same error type fault codes — Motor Type Fault | blocking fault |
| 61-11 | Steer Joystick — Shorted to Supply | blocking fault |
| 61-16 | Steer Joystick — Value at 0 V | blocking fault |
| 61-17 | Steer Joystick — Not Calibrated | blocking fault |
| 63-11 | Steer Angle Sensor — Shorted to Supply | warning / function limited |
| 63-16 | Steer Angle Sensor — Value at 0 V | warning / function limited |
| 63-17 | Steer Angle Sensor — Not Calibrated | warning / function limited |
| 64-11 | Hydraulic Pressure Sensor — Shorted to Supply | warning / function limited |
| 64-16 | Hydraulic Pressure Sensor — Value at 0 V | warning / function limited |
| 64-17 | Hydraulic Pressure Sensor — Not Calibrated | warning / function limited |
| 66-11 | Secondary Boom Angle Sensor — Shorted to Supply | warning / function limited |
| 66-16 | Secondary Boom Angle Sensor — Value at 0 V | warning / function limited |
| 66-17 | Secondary Boom Angle Sensor — Not Calibrated | warning / function limited |
| 66-19 | Secondary Boom Angle Sensor — Out of Range | warning / function limited |
| 68-27 | FUNCTION ENABLE TOGGLE SWITCH (Ground controls) — Active at startup | blocking fault |
| 70-19 | Engine/Pump Electric Motor Speed Mismatch — Out of Range | warning / function limited |
| 70-24 | Pump Electric Motor Speed — TOO LOW | blocking fault |
| 71-21 | Estop Relay — Fault | blocking fault |
| 72-14 | Lift Guard Contact Alarm Switch — Cross check fault | blocking fault |
| 72-21 | Lift Guard Contact Alarm Switch — Generic Fault | warning / function limited |
| 76-12 | Load Sense — Overload | blocking fault |
| 76-13 | Platform Load — No Response | blocking fault |
| 76-14 | Platform Load — Cross check fault | blocking fault |
| 76-15 | Platform Load — Value too low | blocking fault |
| 76-17 | Platform Load — Not Calibrated | blocking fault |
| 76-21 | Platform Load — Internal Fault | blocking fault |
| 76-23 | Platform Load — Value too high | blocking fault |
| 76-31 | Platform Load — Invalid setup | blocking fault |
| 76-36 | Load Sense — Invalid Calibration (crosscheck error) | blocking fault |
| 77-13 | VCON LCD DISPLAY (Platform controls) — No Response | blocking fault |
| 78-13 | PCON CONTROLLER (Platform controls) — No Response | blocking fault |
| 78-29 | PCON CONTROLLER (Platform controls) — Software Version Mismatch | blocking fault |
| 79-13 | ROUND LCD DISPLAY (Ground controls) — No Response | warning / function limited |
| 80-0 | Wall Powered Charger Fault Codes — No Response | warning / function limited |
| 80-1 | Wall Powered Charger Fault Codes — DC-DC failure: LLC excessive leakage fault | blocking fault |
| 80-2 | Wall Powered Charger Fault Codes — PFC failure: PFC excessive leakage fault | blocking fault |
| 80-3 | Wall Powered Charger Fault Codes — PFC has taken too long to boost | blocking fault |
| 80-4 | Wall Powered Charger Fault Codes — The charger has been unable to calibrate the current offset. | blocking fault |
| 80-5 | Wall Powered Charger Fault Codes — The output relay voltage too high when relay is closed. | blocking fault |
| 81-1 | Wall Powered Charger Error Codes — High battery voltage error | warning / function limited |
| 81-2 | Wall Powered Charger Error Codes — Low battery voltage error detected prior to starting a charge cycle | warning / function limited |
| 81-3 | Wall Powered Charger Error Codes — Charge timeout | warning / function limited |
| 81-4 | Wall Powered Charger Error Codes — Battery defective | blocking fault |
| 81-7 | Wall Powered Charger Error Codes — Ah Limit Exceeded | warning / function limited |
| 81-8 | Wall Powered Charger Error Codes — Battery temperature out of range error | warning / function limited |
| 81-11 | Wall Powered Charger Error Codes — Charger is disabled by external command | warning / function limited |
| 81-12 | Wall Powered Charger Error Codes — Reverse polarity error | blocking fault |
| 81-13 | Wall Powered Charger Error Codes — Battery does not take current | warning / function limited |
| 81-16 | Wall Powered Charger Error Codes — Software upgrade failure | warning / function limited |
| 81-17 | Wall Powered Charger Error Codes — USB error | warning / function limited |
| 81-18 | Wall Powered Charger Error Codes — Slot CRC error | warning / function limited |
| 81-19 | Wall Powered Charger Error Codes — Hardware build does not support software version | message |
| 81-20 | Wall Powered Charger Error Codes — No active algorithm selected | warning / function limited |
| 81-21 | Wall Powered Charger Error Codes — High battery voltage error detected while charging | warning / function limited |
| 81-22 | Wall Powered Charger Error Codes — Low battery voltage error detected while charging | warning / function limited |
| 81-23 | Wall Powered Charger Error Codes — High AC voltage error (>270VAC) | warning / function limited |
| 81-24 | Wall Powered Charger Error Codes — Failure to initialize | warning / function limited |
| 81-25 | Wall Powered Charger Error Codes — Low AC voltage oscillation error | warning / function limited |
| 81-26 | Wall Powered Charger Error Codes — Script Failure | warning / function limited |
| 81-27 | Wall Powered Charger Error Codes — USB overcurrent fault | warning / function limited |
| 81-28 | Wall Powered Charger Error Codes — Charge profile incompatibility | warning / function limited |
| 81-29 | Wall Powered Charger Error Codes — CAN Bus error | warning / function limited |
| 81-30 | Wall Powered Charger Error Codes — COMM battery module error | warning / function limited |
| 81-31 | Wall Powered Charger Error Codes — The Vref for the ADC measurements has triggered an alarm | warning / function limited |
| 81-32 | Wall Powered Charger Error Codes — CAN Bus heartbeat error | warning / function limited |
| 81-36 | Wall Powered Charger Error Codes — Battery Temperature Sensor Error | warning / function limited |
| 81-37 | Wall Powered Charger Error Codes — Stalled Cooling Fan Motor | warning / function limited |
| 81-38 | Wall Powered Charger Error Codes — CANOpen reprogramming failed | warning / function limited |
| 82-21 | Load Sense Recovery — Fault | blocking fault |
| 83-20 | Telematics Remote Shutdown — Warning | blocking fault |
| 83-21 | Telematics Remote Disable — Fault | blocking fault |
| 84-13 | Level Sensor — No Response | blocking fault |
| 84-17 | Level Sensor — Not Calibrated | blocking fault |
| 84-21 | Level Sensor — Fault | blocking fault |
| 89-11 | Fuel Level Sensor — Shorted to Supply | message |
| 89-12 | Fuel Level Sensor — Value too high | message |
| 89-16 | Fuel Level Sensor — Value at 0 V | message |
| 95-23 | Engine Rpm — Value too high | warning / function limited |
| 95-24 | Engine Rpm — Value too low | warning / function limited |
| 96-19 | Low Oil Pressure Or Engine Overtemp — Value out of range | blocking fault |
| 97-21 | Motor Braking Fault — Fault | blocking fault |
| 100-16 | Platform Level Up/Down Valve — Shorted to B- | blocking fault |
| 100-21 | Platform Level Up Valve — Fault | blocking fault |
| 100-25 | Platform Level Up Valve — Value too high | blocking fault |
| 100-26 | Platform Level Up Valve — Value too low | blocking fault |
| 101-21 | Platform Level Down Valve — Fault | blocking fault |
| 101-25 | Platform Level Down Valve — Value too high | blocking fault |
| 101-26 | Platform Level Down Valve — Value too low | blocking fault |
| 104-11 | Steer Angle Sensor — Shorted to Supply | warning / function limited |
| 104-12 | Steer Angle Sensor — VALUE TOO HIGH | warning / function limited |
| 104-15 | Steer Angle Sensor — VALUE TOO LOW | warning / function limited |
| 104-16 | Steer Angle Sensor — Value at 0 V | warning / function limited |
| 104-17 | Steer Angle Sensor — Not Calibrated | warning / function limited |
| 131-23 | Battery Voltage — Value too high | blocking fault |
| 131-24 | Battery Voltage — Value too low | blocking fault |
| 135-0 | Wall Powered Charger Fault Codes — No Response | warning / function limited |
| 135-1 | Wall Powered Charger Error Codes — High battery voltage error | warning / function limited |
| 135-2 | Wall Powered Charger Error Codes — Low battery voltage error detected prior to starting a charge cycle | warning / function limited |
| 135-3 | Wall Powered Charger Error Codes — Charge timeout | warning / function limited |
| 135-4 | Wall Powered Charger Error Codes — Battery defective | blocking fault |
| 135-7 | Wall Powered Charger Error Codes — Ah Limit Exceeded | warning / function limited |
| 135-08 | Wall Powered Charger — Component fault | warning / function limited |
| 135-8 | Wall Powered Charger Error Codes — Battery temperature out of range error | warning / function limited |
| 135-11 | Wall Powered Charger Error Codes — Charger is disabled by external command | warning / function limited |
| 135-12 | Wall Powered Charger Error Codes — Reverse polarity error | blocking fault |
| 135-13 | Wall Powered Charger — No Response (detected by TCON, not reported by charger) | warning / function limited |
| 135-16 | Wall Powered Charger Error Codes — Software upgrade failure | warning / function limited |
| 135-17 | Wall Powered Charger Error Codes — USB error | warning / function limited |
| 135-18 | Wall Powered Charger Error Codes — Slot CRC error | warning / function limited |
| 135-19 | Wall Powered Charger Error Codes — Hardware build does not support software version | message |
| 135-20 | Wall Powered Charger Error Codes — No active algorithm selected | warning / function limited |
| 135-21 | Wall Powered Charger Error Codes — High battery voltage error detected while charging | warning / function limited |
| 135-22 | Wall Powered Charger Error Codes — Low battery voltage error detected while charging | warning / function limited |
| 135-23 | Wall Powered Charger Error Codes — High AC voltage error (>270VAC) | warning / function limited |
| 135-24 | Wall Powered Charger Error Codes — Failure to initialize | warning / function limited |
| 135-25 | Wall Powered Charger Error Codes — Low AC voltage oscillation error | warning / function limited |
| 135-26 | Wall Powered Charger Error Codes — Script Failure | warning / function limited |
| 135-27 | Wall Powered Charger Error Codes — USB overcurrent fault | warning / function limited |
| 135-28 | Wall Powered Charger — Charger timeout | warning / function limited |
| 135-29 | Wall Powered Charger — Software version mismatch | warning / function limited |
| 135-30 | Wall Powered Charger Error Codes — COMM battery module error | warning / function limited |
| 135-31 | Wall Powered Charger Error Codes — The Vref for the ADC measurements has I triggered an alarm | warning / function limited |
| 135-32 | Wall Powered Charger Error Codes — CAN Bus heartbeat error | warning / function limited |
| 135-36 | Wall Powered Charger Error Codes — r Battery Temperature ( Sensor Error | warning / function limited |
| 135-37 | Wall Powered Charger Error Codes — Stalled Cooling Fan Motor l | warning / function limited |
| 135-38 | Wall Powered Charger Error Codes — CANOpen reprogramming failed | warning / function limited |
| 135-51 | Wall Powered Charger Fault Codes — DC-DC failure: LLC excessive leakage fault | blocking fault |
| 135-52 | Wall Powered Charger Fault Codes — PFC failure: PFC excessive leakage fault | blocking fault |
| 135-53 | Wall Powered Charger Fault Codes — PFC has taken too long to boost | blocking fault |
| 135-54 | Wall Powered Charger Fault Codes — The charger has been unable to calibrate the current offset. | blocking fault |
| 135-55 | Wall Powered Charger Fault Codes — The output relay voltage too high when relay is closed. | blocking fault |
| 136-0 | Pump [ECON] — No Response | blocking fault |
| 136-08 | Pump / Generator Motor Controller — Component fault | warning / function limited |
| 136-12 | Pump [ECON] — Controller Overcurrent | blocking fault |
| 136-13 | Pump / Generator Motor Controller — No Response | blocking fault |
| 136-14 | Pump [ECON] — Precharge Failed | blocking fault |
| 136-15 | Pump [ECON] — Controller Severe Undertemp | blocking fault |
| 136-16 | Pump [ECON] — Controller Severe Overtemp | blocking fault |
| 136-17 | Pump [ECON] — Severe B+ Undervoltage | warning / function limited |
| 136-18 | Pump [ECON] — Severe B+ Overvoltage | blocking fault |
| 136-22 | Pump [ECON] — Controller Overtemp Cutback | warning / function limited |
| 136-23 | Pump [ECON] — B+ Undervoltage Cutback | warning / function limited |
| 136-24 | Pump [ECON] — B+ Overvoltage Cutback | warning / function limited |
| 136-25 | Pump [ECON] — +5V Supply Failure | warning / function limited |
| 136-26 | Pump [ECON] — Digital Out 6 Overcurrent | warning / function limited |
| 136-27 | Pump [ECON] — Digital Out 7 Overcurrent | warning / function limited |
| 136-28 | Pump [ECON] — Motor Temp Hot Cutback | warning / function limited |
| 136-29 | Pump [ECON] — Motor Temp Sensor Fault | warning / function limited |
| 136-31 | Pump [ECON] — Coil1 Driver Open Short | warning / function limited |
| 136-32 | Pump [ECON] — Coil2 Driver Open/Short | warning / function limited |
| 136-33 | Pump [ECON] — Coil3Driver Open/Short | warning / function limited |
| 136-34 | Pump [ECON] — Coil4Driver Open/Short | warning / function limited |
| 136-35 | Pump [ECON] — PD Open/Short | warning / function limited |
| 136-36 | Pump [ECON] — Encoder Fault | warning / function limited |
| 136-37 | Pump [ECON] — Motor Open | blocking fault |
| 136-38 | Pump [ECON] — Main Contactor Welded | blocking fault |
| 136-39 | Pump [ECON] — Main Contactor Did Not Clo | blocking fault |
| 136-46 | Pump [ECON] — EEPROM Failure | blocking fault |
| 136-47 | Pump [ECON] — HPD/Sequencing Fault | warning / function limited |
| 136-49 | Pump [ECON] — Parameter Change Fault | blocking fault |
| 136-68 | Pump [ECON] — VCL Runtime Error | blocking fault |
| 136-69 | Pump [ECON] — External Supply Out of Ran | warning / function limited |
| 136-71 | Pump [ECON] — OS General | blocking fault |
| 136-72 | Pump [ECON] — PDO Timeout | warning / function limited |
| 136-73 | Pump [ECON] — Stall Detected | warning / function limited |
| 136-77 | Pump [ECON] — Supervisor Fault | blocking fault |
| 136-78 | Pump [ECON] — Supervisor Incompatible | blocking fault |
| 136-82 | Pump [ECON] — Bad Calibrations | blocking fault |
| 136-83 | Pump [ECON] — Driver Supply Fault | blocking fault |
| 136-84 | Pump [ECON] — Following Error Fault | blocking fault |
| 136-87 | Pump [ECON] — Motor Characterization Fau | blocking fault |
| 136-88 | Pump [ECON] — Encoder Steps Count Fault | blocking fault |
| 136-89 | Pump [ECON] — Motor Type Fault | blocking fault |
| 136-91 | Pump [ECON] — Motor Type Fault | blocking fault |
| 136-92 | Pump [ECON] — EM Brake Failed to Set | blocking fault |
| 136-93 | Pump [ECON] — Encoder LOS | warning / function limited |
| 136-98 | Pump [ECON] — Illegal Model Number | blocking fault |
| 136-99 | Pump [ECON] — Parameter Change Fault | blocking fault |
| 137-0 | Left Front Drive Controller — No Response | blocking fault |
| 137-08 | Left Front Motor Controller — Component fault | blocking fault |
| 137-13 | Left Front Motor Controller — No Response | blocking fault |
| 138-0 | Right Front Drive Controller — No Response | blocking fault |
| 138-08 | Right Front Motor Controller — Component fault | blocking fault |
| 138-13 | Right Front Motor Controller — No Response | blocking fault |
| 139-0 | Left Rear Drive Controller — No Response | blocking fault |
| 139-08 | Left Rear Motor Controller — Component fault | blocking fault |
| 139-13 | Left Rear Motor Controller — No Response | blocking fault |
| 139-21 | Left Rear Drive Controller — Fault | blocking fault |
| 140-0 | Pump & Drive Controllers — No Response | blocking fault |
| 140-08 | Right Rear Motor Controller — Component fault | blocking fault |
| 140-12 | Pump & Drive Controllers — Controller Overcurrent | blocking fault |
| 140-13 | Right Rear Motor Controller — No Response | blocking fault |
| 140-14 | Pump & Drive Controllers — Precharge Failed | blocking fault |
| 140-15 | Pump & Drive Controllers — Controller Severe Undertemp | blocking fault |
| 140-16 | Pump & Drive Controllers — Controller Severe Overtemp | blocking fault |
| 140-17 | Pump & Drive Controllers — Severe B+ Undervoltage | warning / function limited |
| 140-18 | Pump & Drive Controllers — Severe B+ Overvoltage | blocking fault |
| 140-21 | Right Front Drive Controller — Fault | blocking fault |
| 140-22 | Pump & Drive Controllers — Controller Overtemp Cutback | warning / function limited |
| 140-23 | Pump & Drive Controllers — B+ Undervoltage Cutback | warning / function limited |
| 140-25 | Pump & Drive Controllers — '+5V Supply Failure | warning / function limited |
| 140-26 | Pump & Drive Controllers — Digital Out 6 Open/Short | blocking fault |
| 140-27 | Pump & Drive Controllers — Digital Out 7 Open/Short | blocking fault |
| 140-28 | Pump & Drive Controllers — Motor Temp Hot Cutback | warning / function limited |
| 140-29 | Pump & Drive Controllers — Motor Temp Sensor Fault | warning / function limited |
| 140-31 | Pump & Drive Controllers — Main Open/Short (RRDCON & ECON only) | blocking fault |
| 140-32 | Pump & Drive Controllers — EMBrake Open/Short (DCON Only) | blocking fault |
| 140-33 | Pump & Drive Controllers — Coil3 Driver Open/Short | blocking fault |
| 140-34 | Pump & Drive Controllers — Coil4 Driver Open/Short | blocking fault |
| 140-35 | Pump & Drive Controllers — PD Open/Short | blocking fault |
| 140-36 | Pump & Drive Controllers — Encoder Fault | blocking fault |
| 140-37 | Pump & Drive Controllers — Motor Open | blocking fault |
| 140-38 | Pump & Drive Controllers — Main Contactor Welded (RRDCON & ECON only) | blocking fault |
| 140-39 | Pump & Drive Controllers — Main Contactor Did Not Close (RRDCON & ECON only) | blocking fault |
| 140-46 | Pump & Drive Controllers — EEPROM Failure | blocking fault |
| 140-49 | Pump & Drive Controllers — Parameter Change Fault | blocking fault |
| 140-68 | Pump & Drive Controllers — VCL Runtime Error | blocking fault |
| 140-71 | Pump & Drive Controllers — OS General | blocking fault |
| 140-72 | Pump & Drive Controllers — PDO Timeout | blocking fault |
| 140-73 | Pump & Drive Controllers — Stall Detected | blocking fault |
| 140-77 | Pump & Drive Controllers — Supervisor Fault | blocking fault |
| 140-78 | Pump & Drive Controllers — Supervisor Incompatible | blocking fault |
| 140-82 | Pump & Drive Controllers — Bad Calibrations | blocking fault |
| 140-83 | Pump & Drive Controllers — Driver Supply Fault | blocking fault |
| 140-84 | Pump & Drive Controllers — Following Error Fault | blocking fault |
| 140-88 | Pump & Drive Controllers — Encoder Pulse Count Fault | blocking fault |
| 140-89 | Pump & Drive Controllers — Motor Type Fault | blocking fault |
| 140-91 | Pump & Drive Controllers — VCL/OS Mismatch | blocking fault |
| 140-92 | Pump & Drive Controllers — EM Brake Failed to Set | blocking fault |
| 140-98 | Pump & Drive Controllers — Illegal Model Number | blocking fault |
| 140-99 | Pump & Drive Controllers — Parameter Mismatch | blocking fault |
| 160-21 | Steer Left Valve — Fault | blocking fault |
| 161-21 | Steer Right Valve — Fault | blocking fault |
| 189-21 | Lift Pump Motor — Fault | blocking fault |
| 189-25 | Lift Pump Motor — Value too high | blocking fault |
| 189-26 | Lift Pump Motor — RESISTANCT TOO LOW | blocking fault |
| 190-12 | AC R MOTOR _ _ AC Motor Right Side — VALUE TOO HIGH | blocking fault |
| 190-15 | AC R MOTOR _ _ AC Motor Right Side — VALUE TOO LOW | blocking fault |
| 190-21 | Right Rear Drive Motor — Fault | blocking fault |
| 190-25 | Right Rear Drive Motor — Value too high | blocking fault |
| 191-12 | AC L MOTOR _ _ AC Motor Left Side — VALUE TOO HIGH | blocking fault |
| 191-15 | AC L MOTOR _ _ AC Motor Left Side — VALUE TOO LOW | blocking fault |
| 191-21 | Left Rear Drive Motor — Fault | blocking fault |
| 191-25 | Left Rear Drive Motor — Value too high | blocking fault |
| 192-21 | Right Front Drive Motor — Fault | blocking fault |
| 192-25 | Right Front Drive Motor — Value too high | blocking fault |
| 193-21 | Left Front Drive Motor — Fault | blocking fault |
| 193-25 | Left Front Drive Motor — Value too high | blocking fault |
| 194-21 | Right Rear Brake Coil — Fault | blocking fault |
| 194-26 | BRAKE RIGHT _ Brake AC Motor Right Side — VALUE TOO LOW | blocking fault |
| 195-21 | Left Rear Brake Coil — Fault | blocking fault |
| 195-26 | BRAKE LEFT _ Brake AC Motor Left Side — VALUE TOO LOW | blocking fault |
| 196-21 | Right Front Brake Coil — Fault | blocking fault |
| 197-21 | Left Front Brake Coil — Fault | blocking fault |
| 198-21 | Right Rear Speed Sensor — Fault | blocking fault |
| 199-21 | Left Rear Speed Sensor — Fault | blocking fault |
| 200-21 | Right Front Speed Sensor — Fault | blocking fault |
| 201-21 | Left Front Speed Sensor — Fault | blocking fault |
| 202-9 | AC R CTRLR _ _ AC Motor Controller Right Side — SHORTED TO B- | blocking fault |
| 202-26 | AC R CTRLR _ _ AC Motor Controller Right Side — RESISTANCE TOO LOW | blocking fault |
| 203-9 | AC L CTRLR _ _ AC Motor Controller Left Side — SHORTED TO B- | blocking fault |
| 203-26 | AC L CTRLR _ _ AC Motor Controller Left Side — RESISTANCE TOO LOW | blocking fault |
| 204-19 | BATTERY _ PWR Battery Power Notes: AUX is available Drive is locked out — OUT OF RANGE | blocking fault |
| 204-21 | Main Battery (Charger) — Fault | blocking fault |
| 204-23 | Main Battery Power Pack Voltage — Value too high | warning / function limited |
| 204-24 | Main Battery Power Pack Voltage — Value too low | warning / function limited |
| 205-12 | Drive Power Contactor — VALUE TOO HIGH | blocking fault |
| 205-13 | Drive Power Contactor — VALUE TOO LOW | blocking fault |
| 205-21 | Drive Power Contactor — Fault | blocking fault |
| 205-26 | Drive Power Contactor — VALUE TOO LOW | blocking fault |
| 205-27 | Drive Power Contactor — Active at startup | blocking fault |
| 233-19 | Battery Temperature (Charger) — Out of Range | blocking fault |
| 233-21 | Battery Temperature (Charger) — Fault | blocking fault |
| 233-23 | Battery Temperature (Charger) — Value too high | blocking fault |
| 253-21 | Capacitor Charge — Fault | blocking fault |
| 254-23 | Battery Charge Voltage — Value too high | warning / function limited |
| 254-24 | Battery Charge Voltage — Value too low | warning / function limited |
| 255-20 | Right Rear Drive Motor Temperature — Warning | warning / function limited |
| 255-21 | Right Rear Drive Motor Temperature — Fault | blocking fault |
| 256-20 | Left Rear Drive Motor Temperature — Warning | warning / function limited |
| 256-21 | Left Rear Drive Motor Temperature — Fault | blocking fault |
| 257-20 | Right Front Drive Motor Temperature — Warning | warning / function limited |
| 257-21 | Right Front Drive Motor Temperature — Fault | blocking fault |
| 258-20 | Left Front Drive Motor Temperature — Warning | warning / function limited |
| 258-21 | Left Front Drive Motor Temperature — Fault | blocking fault |
| 259-20 | Right Rear Drive Controller Temperature — Warning | warning / function limited |
| 259-23 | Right Rear Drive Controller Temperature — Value too high | blocking fault |
| 259-24 | Right Rear Drive Controller Temperature — Value too low | blocking fault |
| 260-20 | Left Rear Drive Controller Temperature — Warning | warning / function limited |
| 260-23 | Left Rear Drive Controller Temperature — Value too high | blocking fault |
| 260-24 | Left Rear Drive Controller Temperature — Value too low | blocking fault |
| 261-20 | Right Front Drive Controller Temperature — Warning | warning / function limited |
| 261-23 | Right Front Drive Controller Temperature — Value too high | blocking fault |
| 261-24 | Right Front Drive Controller Temperature — Value too low | blocking fault |
| 262-20 | Left Front Drive Controller Temperature — Warning | warning / function limited |
| 262-23 | Left Front Drive Controller Temperature — Value too high | blocking fault |
| 262-24 | Left Front Drive Controller Temperature — Value too low | blocking fault |
| 264-23 | Amp Hour Return — Value too high | warning / function limited |
| 265-21 | Charger Usb — Fault | warning / function limited |
| 266-21 | Charge Profile — Fault | blocking fault |
| 266-31 | Charge Profile — Invalid setup | blocking fault |
| 267-23 | Charger Ac Voltage — Value too high | blocking fault |
| 267-24 | Charger Ac Voltage — Value too low | blocking fault |
| 268-21 | Charger Cooling Fan — Fault | warning / function limited |
| 270-21 | Pump Power Contactor — Fault | blocking fault |
| 270-27 | Pump Power Contactor — Active at startup | blocking fault |
| 271-21 | Pump Motor Temperature — Fault | blocking fault |
| 271-23 | Pump Motor Temperature — Value too high | warning / function limited |
| 272-23 | Pump Controller Temperature — Value too high | blocking fault |
| 272-24 | Pump Controller Temperature — Value too low | blocking fault |
| 273-21 | Lift Pump Motor Speed Sensor — Fault | blocking fault |