Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 140-23 — Pump & Drive Controllers — B+ Undervoltage Cutback
Message on the display: Pump & Drive Controllers — B+ Undervoltage Cutback
Code 140-23 occurs in machines: Genie Z-45 DC, Z-45 FE.
warning / function limited
Controller IDs: 136=Pump [ECON] 137=Left Front [LF] 138=Right Front [RF] 139=Left Rear [LR] 140=Right Rear [RR]
Description from the Genie service manual, in the original wording.
Effect on the machine: Reduced drive torque.
Possible causes
- Normal operation. Fault indicates the batteries need recharging. Controller is performance limited at this voltage.
- Battery parameters are mis- adjusted.
- Non-controller system drain on battery.
- Battery resistance too high.
- Battery disconnected while driving.
- See Monitor menu » Battery: Capacitor Voltage.
- Blown B+ fuse or main contactor did not close.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Set: Capacitor bank voltage dropped below the Undervoltage limit with the FET bridge enabled. Clear: Bring capacitor voltage above the Undervoltage limit.
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 140-23 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 140-18Pump & Drive Controllers — Severe B+ Overvoltage
- 140-21Right Front Drive Controller — Fault
- 140-22Pump & Drive Controllers — Controller Overtemp Cutback
- 140-25Pump & Drive Controllers — '+5V Supply Failure
- 140-26Pump & Drive Controllers — Digital Out 6 Open/Short
- 140-27Pump & Drive Controllers — Digital Out 7 Open/Short