609 609 105609 609 104

Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)

Genie error code 205-27 — Drive Power Contactor — Active at startup

Message on the display: Drive Power Contactor — Active at startup

Code 205-27 occurs in machines: Genie Z-60 DC, S-60 DC.

blocking fault

The Genie display shows code 205-27 with the message “Drive Power Contactor — Active at startup”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: No drive functions

Possible causes

  • Main contactor is found closed at power ON (welded contactor)

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Check main contactor wiring Check main contactor for damage Check main contactor contacts

Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 205-27 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes