Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 41-17 — Turntable Joystick — Not Calibrated
Message on the display: Turntable Joystick — Not Calibrated
Code 41-17 occurs in machines: Genie Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC.
blocking fault
The Genie display shows code 41-17 with the message “Turntable Joystick — Not Calibrated”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: Turntable rotate functions disabled
Possible causes
- Not between 2000 & 3000 mV at startup
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Verify: · 5V at JC7-2 (P162PJW OR) · B- at JC7-1 (JSGND BR) · 500 to 4500 mV at JC7-4 & PCON C46-12 (C165TRS WH/RD) through joystick motion
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 41-17 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system