Genie DC and FE electric boom lifts (Z-60 DC, S-60 DC, Z-45 DC, Z-45 FE, Z-33/18 DC)
Genie error code 81-37 — Wall Powered Charger Error Codes — Stalled Cooling Fan Motor
Message on the display: Wall Powered Charger Error Codes — Stalled Cooling Fan Motor
Code 81-37 occurs in machines: Genie Z-60 DC.
warning / function limited
The Genie display shows code 81-37 with the message “Wall Powered Charger Error Codes — Stalled Cooling Fan Motor”. It is a warning: some functions of the machine may be limited until the cause has been removed.
Possible causes
- Fan will not turn when commanded, rotor must be locked
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Fan is obstructed, inspect the fan and clear the blockage.
Source: Genie Service and Repair Manuals (Part No. 1307785, 1299608, 1297714, 1271125, 1268514), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 81-37 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 81-31Wall Powered Charger Error Codes — The Vref for the ADC measurements has triggered an alarm
- 81-32Wall Powered Charger Error Codes — CAN Bus heartbeat error
- 81-36Wall Powered Charger Error Codes — Battery Temperature Sensor Error
- 81-38Wall Powered Charger Error Codes — CANOpen reprogramming failed
- 82-21Load Sense Recovery — Fault
- 83-20Telematics Remote Shutdown — Warning