609 609 105609 609 104

Genie Z-80/60, Z-135/70, S-100, S-105, S-120, S-125: faults by source and type

Genie message — SAFETY SECONDARY BOOM ANGLE SENSOR — VALUE TOO LOW

This message occurs in machines: Genie Z-135/70.

blocking fault

The Genie display shows this message as “SAFETY SECONDARY BOOM ANGLE SENSOR — VALUE TOO LOW”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Primary up, Secondary up/down and Extend disabled, Alarm sounds

Possible causes

The manual does not list the causes for this code: the service technician establishes them during diagnosis of the machine.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Sensor is out of range. Check sensor and actuating pin for proper installation. Repair or replace sensor and recalibrate.

Source: Genie Service Manual Z-80/60 (88619), Service and Repair Manuals Z-135/70 (1268557) and S-100/S-105/S-120/S-125 (102916), Control System Fault Codes tables.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does the message not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie messages of this system