609 609 105609 609 104

Genie with Ford engine (petrol/LPG): ECM engine controller codes

Genie error code 14 — Manifold Absolute Pressure (MAP) sensor low voltage.

Message on the display: Manifold Absolute Pressure (MAP) sensor low voltage.

Code 14 occurs in machines: Genie S-60, S-65, GS-3384 RT, GS-3390, GS-4390, GS-5390, Z-45/25.

warning / function limited

The Genie display shows code 14 with the message “Manifold Absolute Pressure (MAP) sensor low voltage”. It is a warning: some functions of the machine may be limited until the cause has been removed.

Possible causes

  • Faulty MAP sensor.
  • sensor wires shorted to ground.
  • poor terminal connection.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Check for poor terminal connections OR wires shorted to ground OR replace MAP sensor.

Source: Genie Service Manuals S-60/S-65 (65196), S-80/S-85 (111165), Z-80/60 (88619), GS-3384 (82259), GS-3390/4390/5390 (72863), Ford Engine ECM Fault Code Chart.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 14 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes