609 609 105609 609 104

Older Genie GS scissor lifts with LED display (GS-1530, GS-1930, GS-2032, GS-2632, GS-3232, GS-2046, GS-2646, GS-3246)

Genie error code 51 — No pow er output from ECM to the motor controller contactor OR ECM does not sense the motor controller contactor.

Message on the display: No pow er output from ECM to the motor controller contactor OR ECM does not sense the motor controller contactor.

Code 51 occurs in machines: Genie GS-2668 DC, GS-3268 DC, GS-1530, GS-1930, GS-2032, GS-2046, GS-2646, GS-3246.

blocking fault

Only the platform dow n function operates. No other functions operate.

Description from the Genie service manual, in the original wording.

Possible causes

  • Open in w iring from ECM to contactor (ckt A9-Curtis terminal 3).
  • open in brow n ground w ire circuit to contactor.
  • defective contactor.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Check w iring and terminals at motor contactor ckt A9- Curtis terminal 3 OR check w iring and terminal at pin A9, ckt A9-Curtis terminal 3 on the ECM OR replace motor controller contactor.

Source: Genie Service Manual GS-30/32/46 (Part No. 97385) and GS-2046/2646/3246 (Part No. 72972), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.