Genie S-40 XC
Genie error code 185-11 — ESTOP Source — Shorted to supply voltage
Message on the display: ESTOP Source — Shorted to supply voltage
Code 185-11 occurs in machines: Genie S-40 XC.
blocking fault
The Genie display shows code 185-11 with the message “ESTOP Source — Shorted to supply voltage”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: ESTOP circuit cannot complete, preventing machine functions.
Possible causes
- TCON detected that ESTOP 1 is at 12 V but ESTOP 3 is at 0 V.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Check P79PWR (BK, TCON J5-9) and P23PWR (RD, TCON J5-10) for open or short circuits.
Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 185-11 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 179-9Platform Recirculation Coil — Shorted to GND
- 179-11Platform Recirculation Coil — Shorted to supply voltage
- 185-9ESTOP Source — Shorted to GND
- 186-9ESTOP Return — Shorted to GND
- 186-11ESTOP Return — Shorted to supply voltage
- 206-13TCON / PCON — TCON Bank Power Not Detected PCON Bank Power Not Detected