| 1-13 | Engine Can Bus — Not detected | blocking fault |
| 6-19 | Key switch — Fault | blocking fault |
| 7-21 | Engine Warning — Fault | warning / function limited |
| 8-21 | Engine Stop — Fault | blocking fault |
| 11-27 | Engine Start Switch — Active at startup | blocking fault |
| 12-13 | Machine CAN Bus — Not detected | blocking fault |
| 13-27 | Jib Up/Down Switch — Active at startup | blocking fault |
| 14-15 | Alternator — Fault | warning / function limited |
| 15-19 | Foot Switch — Timeout | warning / function limited |
| 15-27 | Foot Switch — Active at startup | warning / function limited |
| 15-28 | Foot Switch — Timeout | warning / function limited |
| 17-9 | Aux Pump Coil — Shorted to GND | blocking fault |
| 17-11 | Aux Pump Coil — Shorted to supply voltage | blocking fault |
| 19-27 | Platform Aux Enable Switch — Active at startup | warning / function limited |
| 21-8 | Pri Boom Up / Down Joystick — Shorted to GND | blocking fault |
| 21-11 | Pri Boom Up / Down Joystick — Shorted to supply voltage | blocking fault |
| 21-27 | Pri Boom Up / Down Joystick — Active at startup | blocking fault |
| 22-9 | Pri Boom Up coil — Shorted to GND | blocking fault |
| 22-11 | Pri Boom Up coil — Shorted to supply voltage | blocking fault |
| 24-13 | Pri Boom Angle — Not detected | blocking fault |
| 24-14 | Pri Boom Angle — Cross check failed | blocking fault |
| 24-17 | Pri Boom Angle — Not calibrated | blocking fault |
| 24-19 | Pri Boom Angle — Value out of expected range | blocking fault |
| 25-21 | Cable tension — Fault | blocking fault |
| 26-9 | Pri Boom Ext Coil — Shorted to GND | blocking fault |
| 26-11 | Pri Boom Ext Coil — Shorted to supply voltage | blocking fault |
| 27-9 | Pri Boom Ret Coil — Shorted to GND | blocking fault |
| 27-11 | Pri Boom Ret Coil — Shorted to supply voltage | blocking fault |
| 35-27 | Ground Control Buttons — Active at startup | warning / function limited |
| 36-9 | Jib Up Coil — Shorted to GND | blocking fault |
| 36-11 | Jib Up Coil — Shorted to supply voltage | blocking fault |
| 40-9 | Jib Select Coil — Shorted to GND | blocking fault |
| 40-11 | Jib Select Coil — Shorted to supply voltage | blocking fault |
| 41-9 | Turntable Rotate Joystick — Shorted to GND | blocking fault |
| 41-11 | Turntable Rotate Joystick — Shorted to supply voltage | blocking fault |
| 41-27 | Turntable Rotate Joystick — Active at startup | blocking fault |
| 42-9 | Turntable Rotate CW Coil — Shorted to GND | blocking fault |
| 42-11 | Turntable Rotate CW Coil — Shorted to supply voltage | blocking fault |
| 43-9 | Turntable Rotate CCW Coil — Shorted to GND | blocking fault |
| 43-11 | Turntable Rotate CCW Coil — Shorted to supply voltage | blocking fault |
| 44-27 | Drive Enable Toggle Switch — Active at startup | warning / function limited |
| 45-27 | Platform Level Toggle Switch — Active at startup | warning / function limited |
| 46-9 | Platform Rotate CW Coil — Shorted to GND | blocking fault |
| 46-11 | Platform Rotate CW Coil — Shorted to supply voltage | blocking fault |
| 47-9 | Platform Rotate CCW Coil — Shorted to GND | blocking fault |
| 47-11 | Platform Rotate CCW Coil — Shorted to supply voltage | blocking fault |
| 51-9 | Drive Joystick — Shorted to GND | blocking fault |
| 51-11 | Drive Joystick — Shorted to supply voltage | blocking fault |
| 51-27 | Drive Joystick — Active at startup | blocking fault |
| 52-9 | Drive Forward Pump Coil — Shorted to GND | blocking fault |
| 52-11 | Drive Forward Pump Coil — Shorted to supply voltage | blocking fault |
| 53-9 | Drive Reverse Pump Coil — Shorted to GND | blocking fault |
| 53-11 | Drive Reverse Pump Coil — Shorted to supply voltage | blocking fault |
| 54-9 | Brake Release Coil — Shorted to GND | blocking fault |
| 54-11 | Brake Release Coil — Shorted to supply voltage | blocking fault |
| 55-9 | High Drive Speed Coil — Shorted to GND | blocking fault |
| 55-11 | High Drive Speed Coil — Shorted to supply voltage | blocking fault |
| 56-13 | Telematics Device — Not detected | message |
| 61-9 | Steer Joystick — Shorted to GND | blocking fault |
| 61-11 | Steer Joystick — Shorted to supply voltage | blocking fault |
| 61-27 | Steer Joystick — Active at startup | blocking fault |
| 62-27 | Prox Override Toggle Switch — Active at startup | warning / function limited |
| 69-9 | AC Generator Output — Shorted to GND | blocking fault |
| 69-11 | AC Generator Output — Shorted to supply voltage | blocking fault |
| 71-9 | TCON — Fault | blocking fault |
| 72-14 | Lift Guard Contact Alarm Switch — Cross check failed | blocking fault |
| 72-21 | Lift Guard Contact Alarm Switch — Fault | blocking fault |
| 73-12 | Engine Oil Pressure — Sensor value too high | blocking fault |
| 73-24 | Engine Oil Pressure — Too low | blocking fault |
| 74-15 | Engine Temperature — Sensor value too low | blocking fault |
| 74-23 | Engine Temperature — Too high | blocking fault |
| 76-13 | Platform Load Sensor — Not detected | blocking fault |
| 76-14 | Platform Load Sensor — Cross check failed | blocking fault |
| 76-15 | Platform Load Sensor — Value to low | blocking fault |
| 76-17 | Platform Load Sensor — Not calibrated | blocking fault |
| 76-21 | Platform Load Sensor — Fault | blocking fault |
| 78-13 | Platform Controller (PCON) — Not detected | blocking fault |
| 78-29 | Platform Controller (PCON) — Software version mismatch | blocking fault |
| 78-36 | Platform Controller (PCON) — Not detected | blocking fault |
| 79-13 | Display Controller (DISCON) — Not detected | blocking fault |
| 79-29 | Display Controller (DISCON) — Software version mismatch | blocking fault |
| 80-13 | Turntable Controller (TCON) — Not detected | blocking fault |
| 80-29 | Turntable Controller (TCON) — Software version mismatch | blocking fault |
| 82-21 | Overload — Recovery | warning / function limited |
| 83-21 | Disabled — By owner | blocking fault |
| 84-13 | Chassis Angle — Not detected | blocking fault |
| 84-17 | Chassis Angle — Not calibrated | blocking fault |
| 84-21 | Chassis Angle — Turntable Tilt Sensor Internal Error. | blocking fault |
| 88-9 | Function Enable Coil — Shorted to GND | blocking fault |
| 88-11 | Function Enable Coil — Shorted to supply voltage | blocking fault |
| 89-12 | Fuel Level Sensor — Sensor value too high | message |
| 89-15 | Fuel Level Sensor — Sensor value too low | message |
| 92-9 | Turntable Rotate Flow Coil — Shorted to GND | blocking fault |
| 92-11 | Turntable Rotate Flow Coil — Shorted to supply voltage | blocking fault |
| 94-13 | Primary Boom Length — Not detected | blocking fault |
| 94-14 | Primary Boom Length — Cross check failed | blocking fault |
| 94-17 | Primary Boom Length — Not calibrated | blocking fault |
| 94-19 | Primary Boom Length — Value out of expected range | blocking fault |
| 95-13 | Engine RPM — Not detected | blocking fault |
| 98-10 | Platform Level Angle — Envelope exceeded | blocking fault |
| 98-13 | Platform Level Angle — Not detected | blocking fault |
| 98-14 | Platform Level Angle — Cross check failed | blocking fault |
| 98-17 | Platform Level Angle — Not calibrated | warning / function limited |
| 98-19 | Platform Level Angle — Value out of expected range | blocking fault |
| 99-9 | Primary Boom Extend / Retract Flow Coil — Shorted to GND | blocking fault |
| 99-11 | Primary Boom Extend / Retract Flow Coil — Shorted to supply voltage | blocking fault |
| 100-9 | Platform Level Up Coil — Shorted to GND | blocking fault |
| 100-11 | Platform Level Up Coil — Shorted to supply voltage | blocking fault |
| 101-9 | Platform Level Down Coil — Shorted to GND | blocking fault |
| 101-11 | Platform Level Down Coil — Shorted to supply voltage | blocking fault |
| 110-27 | Platform Rotate Toggle Switch — Active at startup | warning / function limited |
| 116-13 | Model Configuration — Not detected | blocking fault |
| 116-31 | Model Configuration — Setup invalid | blocking fault |
| 140-10 | Boom — Safety Envelope Exceeded | blocking fault |
| 150-9 | Sensor Power P26PWR — Shorted to GND | blocking fault |
| 150-11 | Sensor Power P26PWR — Shorted to supply voltage | blocking fault |
| 152-9 | Primary Boom Up/Down Flow Coil — Shorted to GND | blocking fault |
| 152-11 | Primary Boom Up/Down Flow Coil — Shorted to supply voltage | blocking fault |
| 160-9 | LF Steer Coil — Shorted to GND | blocking fault |
| 160-11 | LF Steer Coil — Shorted to supply voltage | blocking fault |
| 161-9 | RF Steer Coil — Shorted to GND | blocking fault |
| 161-11 | RF Steer Coil — Shorted to supply voltage | blocking fault |
| 179-9 | Platform Recirculation Coil — Shorted to GND | message |
| 179-11 | Platform Recirculation Coil — Shorted to supply voltage | message |
| 185-9 | ESTOP Source — Shorted to GND | blocking fault |
| 185-11 | ESTOP Source — Shorted to supply voltage | blocking fault |
| 186-9 | ESTOP Return — Shorted to GND | blocking fault |
| 186-11 | ESTOP Return — Shorted to supply voltage | blocking fault |
| 206-13 | TCON / PCON — TCON Bank Power Not Detected PCON Bank Power Not Detected | blocking fault |
| 240-9 | Turntable Sensor Power — P85PWR Short to B- | blocking fault |
| 240-11 | Turntable Sensor Power — P85PWR Short to B+ | blocking fault |
| 241-9 | Turntable Sensor Power — P109PWR is shorted to B- | blocking fault |
| 241-11 | Turntable Sensor Power — P109PWR is shorted to B+ | blocking fault |
| 263-9 | Platform Level Loop Coil — Shorted to GND | message |
| 263-11 | Platform Level Loop Coil — Shorted to supply voltage | message |