Genie error code 24-19 — Pri Boom Angle — Value out of expected range

Message on the display: Pri Boom Angle — Value out of expected range

Code 24-19 occurs in machines: Genie S-40 XC.

blocking fault

The Genie display shows code 24-19 with the message “Pri Boom Angle — Value out of expected range”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Machine limited to recovery functions.

Possible causes

  • Min or max boom angle out of expected range. Crosscheck limit switch disagrees with boom angle sensor.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* Verify that with the boom stowed C68LS (BL, TCON J7-3) is 12V and that the boom is making contact with the LST3S limit switch arm. * Verify that with the boom above 12 degrees C68LS (BL, TCON J7-3) is 0V and that the boom is not making contact with the LST3S limit switch arm. * Check LST3S limit switch for physical damage. * Check bearings in rotary base housing. * Calibrate boom angle sensor.

Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.