609 609 105609 609 104

Genie S-40 XC

Genie error code 55-11 — High Drive Speed Coil — Shorted to supply voltage

Message on the display: High Drive Speed Coil — Shorted to supply voltage

Code 55-11 occurs in machines: Genie S-40 XC.

blocking fault

The Genie display shows code 55-11 with the message “High Drive Speed Coil — Shorted to supply voltage”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Drive functions will not operate.

Possible causes

  • TCON detected that C29MS circuit is shorted to 12 V.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* Verify wiring for C29MS (RD/WH, TCON J2-8) and check for open or short circuits.

Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 55-11 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes