609 609 105609 609 104

Genie S-40 XC

Genie error code 69-9 — AC Generator Output — Shorted to GND

Message on the display: AC Generator Output — Shorted to GND

Code 69-9 occurs in machines: Genie S-40 XC.

blocking fault

The Genie display shows code 69-9 with the message “AC Generator Output — Shorted to GND”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Generator function will not operate.

Possible causes

  • TCON detected that C45GEN circuit is shorted to GND.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* With a voltmeter, measure Y29. Proper resistance should be between 5 - 60 ohms. Replace Y29 if resistance is outside of those values.

Source: Genie Service and Repair Manual S-40 XC (Part No. 1322629, 1286829GT), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 69-9 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes