Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)
Genie error code 143-10 — Primary boom maximum length safety (PBMLS) — Envelope exceeded
Message on the display: Primary boom maximum length safety (PBMLS) — Envelope exceeded
Code 143-10 occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
The Genie display shows code 143-10 with the message “Primary boom maximum length safety (PBMLS) — Envelope exceeded”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: All functions disabled except for corrective direction using AUX (RETRACT)
Possible causes
- Boom length has reached the safety envelope
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
Move boom inside operational envelope
Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 143-10 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 140-08Right rear AC drive controller — Component fault
- 140-13Right rear AC drive controller — Not detected
- 142-10Primary boom maximum angle safety (PBMAS) — Envelope exceeded
- 148-21Sensor Power P85PWR — Fault
- 149-09Sensor Power P109PWR — Shorted to 0V
- 149-11Sensor Power P109PWR — Shorted to Supply Voltage