| 6-21 | Key switch — Fault | blocking fault |
| 15-27 | Foot switch — Active at startup | warning / function limited |
| 15-28 | Foot switch — Timeout | warning / function limited |
| 16-27 | Speed adjustment toggle switch — Active at startup | warning / function limited |
| 17-25 | Auxiliary contactor fault — Resistance too high | blocking fault |
| 17-27 | Auxiliary contactor fault — Active at startup | blocking fault |
| 18-25 | Proportional relief 1 coil — Resistance too high | blocking fault |
| 18-26 | Proportional relief 1 coil — Resistance too low | blocking fault |
| 19-27 | Auxiliary enable toggle switch — Active at startup | warning / function limited |
| 20-11 | Primary boom extend/retract joystick — Shorted to supply | blocking fault |
| 20-16 | Primary boom extend/retract joystick — Value at 0 V | blocking fault |
| 20-17 | Primary boom extend/retract joystick — Not calibrated | blocking fault |
| 21-11 | Pri Boom Up / Down Joystick — Shorted to supply | blocking fault |
| 21-16 | Pri Boom Up / Down Joystick — Value at 0 V | blocking fault |
| 21-17 | Pri Boom Up / Down Joystick — Not calibrated | blocking fault |
| 22-21 | Primary boom up coil — Valve status fault | blocking fault |
| 22-25 | Primary boom up coil — Resistance too high | blocking fault |
| 22-26 | Primary boom up coil — Resistance too low | blocking fault |
| 23-21 | Primary boom down coil — Valve status fault | blocking fault |
| 23-25 | Primary boom down coil — Resistance too high | blocking fault |
| 23-26 | Primary boom down coil — Resistance too low | blocking fault |
| 24-08 | Primary boom angle — Component fault | blocking fault |
| 24-13 | Primary boom angle — Not detected | blocking fault |
| 24-14 | Primary boom angle — Cross check fault | blocking fault |
| 24-17 | Primary boom angle — Not calibrated | blocking fault |
| 24-19 | Primary boom angle — Out of range | blocking fault |
| 24-22 | Primary boom angle — Value not changing | blocking fault |
| 24-30 | Primary boom angle — Calibration mismatch | blocking fault |
| 25-21 | Cable tension — Fault | blocking fault |
| 26-21 | Primary boom extend coil — Valve status fault | blocking fault |
| 27-21 | Primary boom retract coil — Valve status fault | blocking fault |
| 35-27 | Ground Control Station Buttons — Active at startup | warning / function limited |
| 36-21 | Jib up coil — Fault | blocking fault |
| 36-25 | Jib up coil — Resistance too high | blocking fault |
| 36-26 | Jib up coil — Resistance too low | blocking fault |
| 37-21 | Jib down coil — Fault | blocking fault |
| 37-25 | Jib down coil — Resistance too high | blocking fault |
| 37-26 | Jib down coil — Resistance too low | blocking fault |
| 41-11 | Turntable rotate joystick — Shorted to supply | blocking fault |
| 41-16 | Turntable rotate joystick — Value at 0 V | blocking fault |
| 41-17 | Turntable rotate joystick — Not calibrated | blocking fault |
| 42-21 | Turntable rotate CW coil — Valve status fault | blocking fault |
| 43-21 | Turntable Rotate CCW Coil — Valve status fault | blocking fault |
| 43-25 | Turntable Rotate CCW Coil — Resistance too high | blocking fault |
| 43-26 | Turntable Rotate CCW Coil — Resistance too low | blocking fault |
| 44-27 | Drive enable toggle switch — Active at startup | blocking fault |
| 46-21 | Platform Rotate CW Coil — Fault | blocking fault |
| 46-25 | Platform Rotate CW Coil — Resistance too high | blocking fault |
| 46-26 | Platform Rotate CW Coil — Resistance too low | blocking fault |
| 47-21 | Platform rotate CCW coil — Fault | blocking fault |
| 47-25 | Platform rotate CCW coil — Resistance too high | blocking fault |
| 47-26 | Platform rotate CCW coil — Resistance too low | blocking fault |
| 51-11 | Drive joystick — Shorted to supply | blocking fault |
| 51-16 | Drive joystick — Value at 0 V | blocking fault |
| 51-17 | Drive joystick — Not calibrated | blocking fault |
| 61-11 | Steer joystick — Shorted to supply | blocking fault |
| 61-16 | Steer joystick — Value at 0 V | blocking fault |
| 61-17 | Steer joystick — Not calibrated | blocking fault |
| 64-11 | Hydraulic pressure sensor — Shorted to supply | warning / function limited |
| 64-16 | Hydraulic pressure sensor — Value at 0 V | warning / function limited |
| 64-17 | Hydraulic pressure sensor — Not calibrated | warning / function limited |
| 68-27 | Function enable toggle switch — Active at startup | blocking fault |
| 68-28 | Function enable toggle switch — Time out | warning / function limited |
| 71-21 | Emergency Stop relay — Fault | blocking fault |
| 72-14 | Lift guard contact alarm switch — Cross check fault | blocking fault |
| 76-13 | Platform load sensor — Not detected | blocking fault |
| 76-14 | Platform load sensor — Cross check fault | blocking fault |
| 76-15 | Platform load sensor — Value too low | blocking fault |
| 76-17 | Platform load sensor — Not calibrated | blocking fault |
| 76-21 | Platform load sensor — Internal fault | blocking fault |
| 76-23 | Platform load sensor — Value too high | blocking fault |
| 76-31 | Platform load sensor — Invalid setup | blocking fault |
| 77-13 | Platform display (VCON) — Not detected | warning / function limited |
| 77-29 | Platform display (VCON) — Software version mismatch | blocking fault |
| 78-13 | Platform controller (PCON) — Not detected | blocking fault |
| 78-29 | Platform controller (PCON) — Software version mismatch | blocking fault |
| 79-13 | Ground display (DISCON) — Not detected | warning / function limited |
| 79-29 | Ground display (DISCON) — Software version mismatch | blocking fault |
| 80-21 | Turntable controller (TCON) — Fault | blocking fault |
| 82-21 | Load sense recovery — Fault | warning / function limited |
| 83-20 | Disabled by owner — Warning | blocking fault |
| 84-13 | Chassis angle (Primary) — Not detected | blocking fault |
| 84-14 | Chassis angle (Primary) — Cross check fault | blocking fault |
| 84-17 | Chassis angle (Primary) — Not calibrated | blocking fault |
| 84-21 | Chassis angle (Primary) — Fault | blocking fault |
| 85-13 | Chassis angle safety (Secondary) — Not detected | blocking fault |
| 85-17 | Chassis angle safety (Secondary) — Not calibrated | blocking fault |
| 85-21 | Chassis angle safety (Secondary) — Fault | blocking fault |
| 89-12 | Fuel level — Value too high | warning / function limited |
| 89-16 | Fuel level — Value at 0 V | warning / function limited |
| 92-21 | Turntable rotate flow coil — Fault | blocking fault |
| 92-25 | Turntable rotate flow coil — Resistance too high | blocking fault |
| 92-26 | Turntable rotate flow coil — Resistance too low | blocking fault |
| 94-13 | Primary boom length — Not detected | blocking fault |
| 94-14 | Primary boom length — Cross check fault | blocking fault |
| 94-17 | Primary boom length — Not calibrated | blocking fault |
| 94-19 | Primary boom length — Out of range | blocking fault |
| 94-22 | Primary boom length — Value not changing | blocking fault |
| 94-30 | Primary boom length — Calibration mismatch | blocking fault |
| 95-23 | Engine RPM — Too high | warning / function limited |
| 95-24 | Engine RPM — Too low | warning / function limited |
| 96-19 | Low oil pressure or engine overtemp — Out of range | blocking fault |
| 97-21 | Drive motor speed — Fault | blocking fault |
| 98-08 | Platform level angle — Component fault | blocking fault |
| 98-10 | Platform level angle — Envelope exceeded | blocking fault |
| 98-13 | Platform level angle — Not detected | blocking fault |
| 98-14 | Platform level angle — Cross check fault | blocking fault |
| 98-17 | Platform level angle — Not calibrated | blocking fault |
| 98-19 | Platform level angle — Out of range | blocking fault |
| 98-22 | Platform level angle — Value not changing | blocking fault |
| 98-30 | Platform level angle — Calibration mismatch | blocking fault |
| 99-21 | Primary boom extend/retract flow coil — Fault | blocking fault |
| 99-25 | Primary boom extend/retract flow coil — Resistance too high | blocking fault |
| 99-26 | Primary boom extend/retract flow coil — Resistance too low | blocking fault |
| 100-21 | Platform level up coil — Fault | blocking fault |
| 100-25 | Platform level up coil — Resistance too high | blocking fault |
| 100-26 | Platform level up coil — Resistance too low | blocking fault |
| 101-21 | Platform level down coil — Fault | blocking fault |
| 101-25 | Platform level down coil — Resistance too high | blocking fault |
| 101-26 | Platform level down coil — Resistance too low | blocking fault |
| 104-11 | Front steer angle — Shorted to supply | warning / function limited |
| 104-16 | Front steer angle — Value at 0 V | warning / function limited |
| 104-17 | Front steer angle — Not calibrated | warning / function limited |
| 116-20 | Model configuration — Warning | warning / function limited |
| 116-31 | Model configuration — Invalid setup | blocking fault |
| 130-23 | Battery current — Too high | blocking fault |
| 131-23 | Battery voltage — Too high | blocking fault |
| 131-24 | Battery voltage — Too low | blocking fault |
| 135-08 | Wall powered charger — Component fault | warning / function limited |
| 135-13 | Wall powered charger — Not detected | warning / function limited |
| 135-28 | Wall powered charger — Charge timeout | warning / function limited |
| 135-29 | Wall powered charger — Software version mismatch | blocking fault |
| 136-08 | Pump motor controller 1 — Component fault | blocking fault |
| 136-13 | Pump motor controller 1 — Not detected | blocking fault |
| 137-08 | Left front AC drive controller — Component fault | blocking fault |
| 137-13 | Left front AC drive controller — Not detected | blocking fault |
| 138-08 | Right front AC drive controller — Component fault | blocking fault |
| 138-13 | Right front AC drive controller — Not detected | blocking fault |
| 139-08 | Left rear AC drive controller — Component fault | blocking fault |
| 139-13 | Left rear AC drive controller — Not detected | blocking fault |
| 140-08 | Right rear AC drive controller — Component fault | blocking fault |
| 140-13 | Right rear AC drive controller — Not detected | blocking fault |
| 142-10 | Primary boom maximum angle safety (PBMAS) — Envelope exceeded | blocking fault |
| 143-10 | Primary boom maximum length safety (PBMLS) — Envelope exceeded | blocking fault |
| 148-21 | Sensor Power P85PWR — Fault | blocking fault |
| 149-09 | Sensor Power P109PWR — Shorted to 0V | blocking fault |
| 149-11 | Sensor Power P109PWR — Shorted to Supply Voltage | blocking fault |
| 149-23 | Sensor Power P109PWR — Value too high | blocking fault |
| 149-24 | Sensor Power P109PWR — Value too low | blocking fault |
| 152-21 | Primary Down On/Off Valve — Valve status fault | blocking fault |
| 189-25 | Lift Pump Motor 1 — Resistance Too High | blocking fault |
| 190-25 | RR Drive Motor — Resistance Too High | blocking fault |
| 191-25 | LR Drive Motor — Resistance Too High | blocking fault |
| 192-25 | RF Drive Motor — Resistance Too High | blocking fault |
| 193-25 | LF Drive Motor — Resistance Too High | blocking fault |
| 194-21 | RR Brake Coil — Fault | blocking fault |
| 195-21 | LR Brake Coil — Fault | blocking fault |
| 196-21 | RF Brake Coil — Fault | blocking fault |
| 197-21 | LF Brake Coil — Fault | blocking fault |
| 198-21 | RR Speed Sensor — Fault | blocking fault |
| 199-21 | LR Speed Sensor — Fault | blocking fault |
| 200-21 | RF Speed Sensor — Fault | blocking fault |
| 201-21 | LF Speed Sensor — Fault | blocking fault |
| 204-21 | Main Battery — Fault | blocking fault |
| 205-21 | Drive Power Contactor — Fault | blocking fault |
| 205-27 | Drive Power Contactor — Active ON at Start Up | blocking fault |
| 233-19 | Battery Temperature — Out of Range | blocking fault |
| 233-21 | Battery Temperature — Fault | blocking fault |
| 233-23 | Battery Temperature — Too High | blocking fault |
| 233-24 | Battery Temperature — Too Low | blocking fault |
| 252-13 | Battery Management System (BMS) — No Response | blocking fault |
| 252-21 | Battery Management System (BMS) — Component Fault | blocking fault |
| 253-21 | Capacitor Charge — Fault | blocking fault |
| 254-23 | Battery Charge Voltage — Too High | warning / function limited |
| 254-24 | Battery Charge Voltage — Too Low | warning / function limited |
| 255-20 | Right Rear Drive Motor Temperature — Warning | warning / function limited |
| 255-21 | Right Rear Drive Motor Temperature — Fault | blocking fault |
| 256-20 | Left Rear Drive Motor Temperature — Warning | warning / function limited |
| 256-21 | Left Rear Drive Motor Temperature — Fault | blocking fault |
| 257-20 | Right Front Drive Motor Temperature — Warning | warning / function limited |
| 257-21 | Right Front Drive Motor Temperature — Fault | blocking fault |
| 258-20 | Left Front Drive Motor Temperature — Warning | warning / function limited |
| 258-21 | Left Front Drive Motor Temperature — Fault | blocking fault |
| 259-20 | Right Rear Drive Controller Temperature — Warning | warning / function limited |
| 259-23 | Right Rear Drive Controller Temperature — Too High | blocking fault |
| 259-24 | Right Rear Drive Controller Temperature — Too Low | blocking fault |
| 260-20 | Left Rear Drive Controller Temperature — Warning | warning / function limited |
| 260-23 | Left Rear Drive Controller Temperature — Too High | blocking fault |
| 260-24 | Left Rear Drive Controller Temperature — Too Low | blocking fault |
| 261-20 | Right Front Drive Controller Temperature — Warning | warning / function limited |
| 261-23 | Right Front Drive Controller Temperature — Too High | blocking fault |
| 261-24 | Right Front Drive Controller Temperature — Too Low | blocking fault |
| 262-20 | Left Font Drive Controller Temperature — Warning | warning / function limited |
| 262-23 | Left Font Drive Controller Temperature — Too High | blocking fault |
| 262-24 | Left Font Drive Controller Temperature — Too Low | blocking fault |
| 264-23 | Amp Hour Return — Too High | warning / function limited |
| 265-21 | Charger USB — Fault | warning / function limited |
| 266-21 | Charge Profile — Fault | blocking fault |
| 266-31 | Charge Profile — Setup Invalid | blocking fault |
| 267-23 | Charger AC Voltage — Too High | blocking fault |
| 267-24 | Charger AC Voltage — Too Low | blocking fault |
| 268-21 | Charger Cooling Fan — Fault | warning / function limited |
| 270-21 | Pump Controller 1 Contactor — Fault | blocking fault |
| 270-27 | Pump Controller 1 Contactor — Active at Startup | blocking fault |
| 271-21 | Pump Motor 1 Temperature — Fault | blocking fault |
| 271-23 | Pump Motor 1 Temperature — Too High | warning / function limited |
| 272-20 | Pump Controller 1 Temperature — Warning | warning / function limited |
| 272-23 | Pump Controller 1 Temperature — Too High | blocking fault |
| 272-24 | Pump Controller 1 Temperature — Too Low | blocking fault |
| 273-21 | Pump Motor 1 Speed Sensor — Fault | blocking fault |
| 274-08 | Pump Motor Controller 2 — Component Fault | blocking fault |
| 274-13 | Pump Motor Controller 2 — No Response | blocking fault |
| 274-31 | Pump Motor Controller 2 — Setup Invalid | blocking fault |
| 275-21 | Pump Controller 2 Contactor — Fault | blocking fault |
| 275-27 | Pump Controller 2 Contactor — Active at Startup | blocking fault |
| 276-20 | Pump Controller 2 Temperature — Warning | warning / function limited |
| 276-23 | Pump Controller 2 Temperature — Too High | blocking fault |
| 276-24 | Pump Controller 2 Temperature — Too Low | blocking fault |
| 277-21 | Pump Motor 2 Temperature — Fault | blocking fault |
| 277-23 | Pump Motor 2 Temperature — Too High | warning / function limited |
| 278-21 | Pump Motor 2 Speed Sensor — Fault | blocking fault |
| 279-08 | Welder Motor Controller — Component Fault | blocking fault |
| 279-13 | Welder Motor Controller — No Response | blocking fault |
| 280-21 | Welder Controller Contactor — Fault | blocking fault |
| 280-27 | Welder Controller Contactor — Active at Startup | blocking fault |
| 281-23 | Welder Controller Temperature — Too High | blocking fault |
| 281-24 | Welder Controller Temperature — Too Low | blocking fault |
| 282-21 | Welder Motor Temperature — Fault | blocking fault |
| 282-23 | Welder Motor Temperature — Too High | warning / function limited |
| 283-21 | Welder Motor Speed Sensor — Fault | blocking fault |
| 284-25 | Proportional Relief 2 Coil — Resistance Too High | blocking fault |
| 284-26 | Proportional Relief 2 Coil — Resistance Too Low | blocking fault |
| 285-25 | Proportional Relief 3 Coil — Resistance Too High | blocking fault |
| 285-26 | Proportional Relief 3 Coil — Resistance Too Low | blocking fault |
| 286-21 | Lift Pump Motor 2 — Fault | blocking fault |
| 286-25 | Lift Pump Motor 2 — Resistance Too High | blocking fault |
| 287-21 | Welder Motor — Fault | blocking fault |
| 287-25 | Welder Motor — Resistance Too High | blocking fault |
| 288-9 | P198 Sensor Power — Shorted to 0V | blocking fault |
| 288-11 | P198 Sensor Power — Shorted to Supply Voltage | blocking fault |
| 288-23 | P198 Sensor Power — Too High | blocking fault |
| 288-24 | P198 Sensor Power — Too Low | blocking fault |
| 289-23 | TCON System Power — Too High | blocking fault |
| 289-24 | TCON System Power — Too Low | blocking fault |
| 290-23 | PCON System Power — Too High | blocking fault |
| 290-24 | PCON System Power — Too Low | blocking fault |
| 291-27 | Platform Control Buttons — Active at Startup | blocking fault |
| 292-17 | Hydraulic Pump 1 — Not Calibrated | warning / function limited |
| 293-17 | Hydraulic Pump 2 — Not Calibrated | warning / function limited |
| 294-17 | Hydraulic Pump 3 — Not Calibrated | warning / function limited |