609 609 105609 609 104

Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)

Genie error code 191-25 — LR Drive Motor — Resistance Too High

Message on the display: LR Drive Motor — Resistance Too High

Code 191-25 occurs in machines: Genie S-85 XC FE, S-85 XC E.

blocking fault

The Genie display shows code 191-25 with the message “LR Drive Motor — Resistance Too High”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: EM brake set. Main Contactor Open. No Drive of failed motor. Reduces machine drive speed.

Possible causes

  • Motor phase is open. Bad crimps or faulty wiring.

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

Check motor power (UVW) cables. Confirm motor power cable connections.

Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 191-25 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes