Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)
Genie error code 284-26 — Proportional Relief 2 Coil — Resistance Too Low
Message on the display: Proportional Relief 2 Coil — Resistance Too Low
Code 284-26 occurs in machines: Genie S-85 XC FE, S-85 XC E.
blocking fault
The Genie display shows code 284-26 with the message “Proportional Relief 2 Coil — Resistance Too Low”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: Fault condition. Recover using AUX Power
Possible causes
- Short or Resistance < 50% of nominal
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
*Check Ω *Check no open/short circuit between controller and B- (V241HGP OR/RD)
Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 284-26 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system