609 609 105609 609 104

Genie S-85 XC FE and S-85 XC E (hybrid and electric drive)

Genie error code 46-26 — Platform Rotate CW Coil — Resistance too low

Message on the display: Platform Rotate CW Coil — Resistance too low

Code 46-26 occurs in machines: Genie S-85 XC FE, S-85 XC E.

blocking fault

The Genie display shows code 46-26 with the message “Platform Rotate CW Coil — Resistance too low”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.

Effect on the machine: Associated function disabled

Possible causes

  • Short circuit or Ohms <50% of nominal

What you can do

Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.

Solution from the manual

* Check Ohms (~29Ω). * Check for open/short circuit between controller and B- (V17PRL GR).

Source: Genie Service and Repair Manual S-85 XC FE / E (Part No. 1337498), Fault Codes section.

The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.

Does code 46-26 not go away?

RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.

Book a service

Genie service · Genie parts · All Genie codes of this system

Neighbouring Genie codes