Genie XC, HF and J boom lifts (S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 J, S-80 J)
Genie error code 110-27 — Platform Rotate Toggle Switch — Active at startup
Message on the display: Platform Rotate Toggle Switch — Active at startup
Code 110-27 occurs in machines: Genie S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 J, S-80 J.
warning / function limited
The Genie display shows code 110-27 with the message “Platform Rotate Toggle Switch — Active at startup”. It is a warning: some functions of the machine may be limited until the cause has been removed.
Effect on the machine: Platform Rotate Left or Right will not operate, depending on which side of the switch was faulted.
Possible causes
- Toggle switch input was detected as HIGH at start-up.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Verify with a voltmeter that the Platform Rotate Toggle Switch (TS7) is operating properly. * C17PRL (GR, PCON J16-4) and C18PRR (GR/BK, PCON J17-5) should be 12 V when the switch is pressed in their respective directions. * Cycle power to allow the machine to re- test the fault.
Source: Genie Service and Repair Manuals (Part No. 1316494, 1315679, 1288652, 1280490, 1285305, 1285307), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 110-27 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.
Genie service · Genie parts · All Genie codes of this system
Neighbouring Genie codes
- 101-11Platform Level Down Coil — Shorted to supply voltage
- 101-12Platform Level Down Valve — Circuit shorted to V+
- 101-15Platform Level Down Valve — Circuit shorted to GND
- 116-13Model Configuration — Model Config Not Detected
- 116-31Model Configuration — Setup invalid
- 141-10Boom — Safety Envelope Exceeded