| 1-13 | Engine Can Bus — Not detected | blocking fault |
| 6-19 | Key switch — Fault | blocking fault |
| 7-21 | Engine Warning — Fault | warning / function limited |
| 8-21 | Engine Stop — Fault | blocking fault |
| 9-21 | Engine — Fault | warning / function limited |
| 10-27 | Ground Controls Engine Start Switch — Active at startup | warning / function limited |
| 11-19 | Engine Start Toggle Switch — Stuck ON at power up. | warning / function limited |
| 11-27 | Platform Controls Engine Start Switch — Active at startup | warning / function limited |
| 12-13 | Machine CAN Bus — Not detected | blocking fault |
| 12-29 | CAN Bus — System not functioning | blocking fault |
| 13-19 | Jib Up/Down Toggle Switch — Stuck ON at power up. | warning / function limited |
| 13-27 | Jib Up/Down Switch — Active at startup | warning / function limited |
| 14-15 | Alternator — Fault | warning / function limited |
| 15-19 | Foot Switch — Stuck ON at power up, or timeout occurred. | warning / function limited |
| 15-27 | Foot Switch — Active at startup | warning / function limited |
| 15-28 | Foot Switch — Timeout | warning / function limited |
| 17-11 | Aux Pump Coil — Shorted to supply voltage | blocking fault |
| 19-12 | APU Solenoid and Switch — Solenoid output shorted to V+ | blocking fault |
| 19-15 | APU Solenoid and Switch — Solenoid output shorted to GND | blocking fault |
| 19-19 | APU Solenoid and Switch — Stuck ON at power up. | warning / function limited |
| 19-27 | Platform Aux Enable Switch — Active at startup | warning / function limited |
| 20-11 | Pri Boom Ext / Ret Joystick — Shorted to supply voltage | blocking fault |
| 20-12 | Primary Boom Extend / Retract Joystick — Joystick voltage too high. | blocking fault |
| 20-15 | Primary Boom Extend / Retract Joystick — Joystick voltage too low. | blocking fault |
| 20-19 | Primary Boom Extend / Retract Joystick — Joystick held at startup. | warning / function limited |
| 20-27 | Pri Boom Ext / Ret Joystick — Active at startup | warning / function limited |
| 21-11 | Pri Boom Up / Down Joystick — Shorted to supply voltage | blocking fault |
| 21-12 | Primary Boom Up / Down Joystick — Joystick voltage too high. | blocking fault |
| 21-15 | Primary Boom Up / Down Joystick — Joystick voltage too low. | blocking fault |
| 21-19 | Primary Boom Up / Down Joystick — Joystick held at startup. | warning / function limited |
| 21-27 | Active at startup | warning / function limited |
| 21-28 | startup | warning / function limited |
| 22-11 | Pri Boom Up coil — Shorted to supply voltage | blocking fault |
| 22-12 | Primary Boom Up Valve — Circuit shorted to V+ | blocking fault |
| 22-15 | Primary Boom Up Valve — Circuit shorted to GND | blocking fault |
| 23-11 | Pri Boom Down Coil — Shorted to supply voltage | blocking fault |
| 23-12 | Primary Boom Down Valve — Circuit shorted to V+ | blocking fault |
| 23-15 | Primary Boom Down Valve — Circuit shorted to GND | blocking fault |
| 24-13 | Pri Boom Angle — Not detected | blocking fault |
| 24-14 | Pri Boom Angle — Cross check failed | blocking fault |
| 24-17 | Pri Boom Angle — Not calibrated | blocking fault |
| 24-19 | Pri Boom Angle — Value out of expected range | blocking fault |
| 24-36 | Boom Angle Sensor — Internal check | blocking fault |
| 25-21 | Cable tension — Fault | blocking fault |
| 26-11 | Pri Boom Ext Coil — Shorted to supply voltage | blocking fault |
| 26-12 | Primary Boom Extend Valve — Circuit shorted to V+ | blocking fault |
| 26-15 | Primary Boom Extend Valve — Circuit shorted to GND | blocking fault |
| 27-11 | Pri Boom Ret Coil — Shorted to supply voltage | blocking fault |
| 27-12 | Primary Boom Retract Valve — Circuit shorted to V+ | blocking fault |
| 27-15 | Primary Boom Retract Valve — Circuit shorted to GND | blocking fault |
| 35-19 | Ground Buttons — Held at startup | warning / function limited |
| 35-27 | Ground Control Buttons — Active at startup | warning / function limited |
| 36-11 | Jib Up Coil — Shorted to supply voltage | blocking fault |
| 36-12 | Jib Up Valve — Circuit shorted to V+ | blocking fault |
| 36-15 | Jib Up Valve — Circuit shorted to GND | blocking fault |
| 37-11 | Jib Down Coil — Shorted to supply voltage | blocking fault |
| 37-12 | Jib Down Valve — Circuit shorted to V+ | blocking fault |
| 37-15 | Jib Down Valve — Circuit shorted to GND | blocking fault |
| 40-11 | Jib Select Coil — Shorted to supply voltage | blocking fault |
| 41-11 | Turntable Rotate Joystick — Shorted to supply voltage | blocking fault |
| 41-12 | Turntable Rotate Joystick — Joystick voltage too high. | blocking fault |
| 41-15 | Turntable Rotate Joystick — Joystick voltage too low. | blocking fault |
| 41-19 | Turntable Rotate Joystick — Joystick held at startup. | warning / function limited |
| 41-27 | Turntable Rotate Joystick — Active at startup | warning / function limited |
| 42-11 | Turntable Rotate CW Coil — Shorted to supply voltage | blocking fault |
| 42-12 | Turntable Rotate CW Valve — Circuit shorted to V+ | blocking fault |
| 42-15 | Turntable Rotate CW Valve — Circuit shorted to GND | blocking fault |
| 43-11 | Turntable Rotate CCW Coil — Shorted to supply voltage | blocking fault |
| 43-12 | Turntable Rotate CCW Valve — Circuit shorted to V+ | blocking fault |
| 43-15 | Turntable Rotate CCW Valve — Circuit shorted to GND | blocking fault |
| 44-19 | Drive Enable Switch — Stuck ON at power up. | warning / function limited |
| 44-27 | Drive Enable Toggle Switch — Active at startup | warning / function limited |
| 45-19 | Platform Level Up/Down Switch — Stuck ON at power up. | warning / function limited |
| 45-27 | Platform Level Toggle Switch — Active at startup | warning / function limited |
| 46-11 | Platform Rotate CW Coil — Shorted to supply voltage | blocking fault |
| 46-12 | Platform Rotate CW Valve — Circuit shorted to V+ | blocking fault |
| 46-15 | Platform Rotate CW Valve — Circuit shorted to GND | blocking fault |
| 47-11 | Platform Rotate CCW Coil — Shorted to supply voltage | blocking fault |
| 47-12 | Platform Rotate CCW Valve — Circuit shorted to V+ | blocking fault |
| 47-15 | Platform Rotate CCW Valve — Circuit shorted to GND | blocking fault |
| 51-11 | Drive Joystick — Shorted to supply voltage | blocking fault |
| 51-12 | Drive Forward / Reverse Joystick — Joystick voltage too high. | blocking fault |
| 51-15 | Drive Forward / Reverse Joystick — Joystick voltage too low. | blocking fault |
| 51-19 | Drive Forward / Reverse Joystick — Joystick held at startup. | warning / function limited |
| 51-27 | Drive Joystick — Active at startup | warning / function limited |
| 52-11 | Drive Forward Pump Coil — Shorted to supply voltage | blocking fault |
| 52-12 | Drive Forward Valve — Circuit shorted to V+ | blocking fault |
| 52-15 | Drive Forward Valve — Circuit shorted to GND | blocking fault |
| 53-11 | Drive Reverse Pump Coil — Shorted to supply voltage | blocking fault |
| 53-12 | Drive Reverse Valve — Circuit shorted to V+ | blocking fault |
| 53-15 | Drive Reverse Valve — Circuit shorted to GND | blocking fault |
| 54-11 | Brake Release Coil — Shorted to supply voltage | blocking fault |
| 54-12 | Brake Release Valve — Circuit shorted to V+ | blocking fault |
| 54-15 | Brake Release Valve — Circuit shorted to GND | blocking fault |
| 55-11 | High Drive Speed Coil — Shorted to supply voltage | blocking fault |
| 55-12 | Motor Stroke Valve — Circuit shorted to V+ | blocking fault |
| 55-15 | Motor Stroke Valve — Circuit shorted to GND | blocking fault |
| 56-13 | Telematics Device — Not detected | message |
| 61-11 | Steer Joystick — Shorted to supply voltage | blocking fault |
| 61-12 | Steer Joystick — Joystick voltage too high. | blocking fault |
| 61-15 | Steer Joystick — Joystick voltage too low. | blocking fault |
| 61-19 | Steer Joystick — Joystick held at startup. | warning / function limited |
| 61-27 | Steer Joystick — Active at startup | warning / function limited |
| 62-27 | Prox Override Toggle Switch — Active at startup | warning / function limited |
| 68-21 | Safety Envelope Fault — Out of range | blocking fault |
| 68-27 | Ground Function Enable Button — Active at startup | warning / function limited |
| 69-11 | AC Generator Output — Shorted to supply voltage | blocking fault |
| 69-12 | Generator Control Circuit — Circuit shorted to V+ | blocking fault |
| 69-15 | Generator Control Circuit — Circuit shorted to GND | blocking fault |
| 71-15 | ESTOP Circuit — ESTOP Return circuit shorted to GND | blocking fault |
| 71-16 | TCON — Fault | blocking fault |
| 71-21 | ESTOP Circuit — ESTOP Return circuit mismatch | blocking fault |
| 71-22 | ESTOP Circuit — ESTOP Source circuit is shorted to GND | blocking fault |
| 71-31 | ESTOP Circuit — ESTOP Source circuit mismatch | blocking fault |
| 72-14 | Lift Guard Contact Alarm Switch — Cross check failed | blocking fault |
| 72-21 | Lift Guard Contact Alarm Switch — Fault | blocking fault |
| 72-36 | Contact Alarm — Switch state mismatch | blocking fault |
| 73-12 | Engine Oil Pressure — Sensor value too high | blocking fault |
| 73-24 | Engine Oil Pressure — Too low | blocking fault |
| 74-15 | Engine Temperature — Sensor value too low | blocking fault |
| 74-23 | Engine Temperature — Too high | blocking fault |
| 75-34 | TCON Secondary Processor Software — Incorrect software version | blocking fault |
| 76-13 | Platform Load Sensor — Not detected | blocking fault |
| 76-14 | Platform Load Sensor — Cross check failed | blocking fault |
| 76-15 | Platform Load Sensor — Value to low | blocking fault |
| 76-17 | Platform Load Sensor — Not calibrated | blocking fault |
| 76-21 | Platform Load Sensor — Fault | blocking fault |
| 77-21 | Platform Overload Detection — Internal check | blocking fault |
| 78-13 | Platform Controller (PCON) — Not detected | blocking fault |
| 78-29 | Platform Controller (PCON) — Software version mismatch | blocking fault |
| 78-34 | Platform Controller (PCON) — Incorrect software version | blocking fault |
| 78-36 | Platform Controller (PCON) — Secondary processor not detected. | blocking fault |
| 79-13 | Display Controller (DISCON) — Not detected | blocking fault |
| 79-29 | Display Controller (DISCON) — Software version mismatch | blocking fault |
| 79-34 | Display Controller (DISCON) — Incorrect software version | blocking fault |
| 80-13 | Turntable Controller (TCON) — Not detected | blocking fault |
| 80-20 | Turntable Controller (TCON) — Remote disable | blocking fault |
| 80-29 | Turntable Controller (TCON) — Software version mismatch | blocking fault |
| 80-36 | Turntable Controller (TCON) — Incorrect software version | blocking fault |
| 82-21 | Overload — Recovery | message |
| 83-20 | Disabled — By owner | blocking fault |
| 83-21 | Disabled — By owner | blocking fault |
| 84-13 | Chassis Angle — Not detected | blocking fault |
| 84-17 | Chassis Angle — Not calibrated | blocking fault |
| 84-21 | Chassis Angle — Turntable Tilt Sensor Internal Error. | blocking fault |
| 85-13 | Chassis Angle Safety — Not detected | blocking fault |
| 88-11 | Function Enable Coil — Shorted to supply voltage | blocking fault |
| 88-12 | Function Enable Valve — Circuit shorted to V+ | blocking fault |
| 88-15 | Function Enable Valve — Circuit shorted to GND | blocking fault |
| 89-12 | Fuel Level Sensor — Value to high | message |
| 89-15 | Fuel Level Sensor — Value to low | message |
| 92-11 | Turntable Rotate Flow Coil — Shorted to supply voltage | blocking fault |
| 92-12 | Turntable Rotate Flow Valve — Circuit shorted to V+ | blocking fault |
| 92-15 | Turntable Rotate Flow Valve — Circuit shorted to GND | blocking fault |
| 94-13 | Primary Boom Length — Not detected | blocking fault |
| 94-14 | Primary Boom Length — Cross check failed | blocking fault |
| 94-17 | Primary Boom Length — Not calibrated | blocking fault |
| 94-19 | Primary Boom Length — Value out of expected range | blocking fault |
| 94-36 | Boom Length Sensor — Internal check | blocking fault |
| 95-13 | Engine RPM Not Detected — Not detected | blocking fault |
| 96-21 | Engine Oil Pressure — Value too low | blocking fault |
| 98-10 | Platform Level Angle — Envelope exceeded | blocking fault |
| 98-13 | Platform Level Angle — Not detected | blocking fault |
| 98-14 | Platform Level Angle — Cross Check Fault | blocking fault |
| 98-17 | Platform Level Angle — Not calibrated | blocking fault |
| 98-19 | Platform Level Angle — Out of range | blocking fault |
| 99-11 | Primary Boom Extend / Retract Flow Coil — Shorted to supply voltage | blocking fault |
| 100-11 | Platform Level Up Coil — Shorted to supply voltage | blocking fault |
| 100-12 | Platform Level Up Valve — Circuit shorted to V+ | blocking fault |
| 100-15 | Platform Level Up Valve — Circuit shorted to GND | blocking fault |
| 101-11 | Platform Level Down Coil — Shorted to supply voltage | blocking fault |
| 101-12 | Platform Level Down Valve — Circuit shorted to V+ | blocking fault |
| 101-15 | Platform Level Down Valve — Circuit shorted to GND | blocking fault |
| 110-27 | Platform Rotate Toggle Switch — Active at startup | warning / function limited |
| 116-13 | Model Configuration — Model Config Not Detected | blocking fault |
| 116-31 | Model Configuration — Setup invalid | blocking fault |
| 141-10 | Boom — Safety Envelope Exceeded | blocking fault |
| 150-11 | Sensor Power P26PWR — Shorted to supply voltage | blocking fault |
| 150-21 | Platform Overload Recovery — Condition occurred | warning / function limited |
| 152-11 | Primary Boom Up/Down Flow Coil — Shorted to supply voltage | blocking fault |
| 152-12 | Primary Boom Up/Down Flow Valve — Circuit shorted to V+ | blocking fault |
| 152-15 | Primary Boom Up/Down Flow Valve — Circuit shorted to GND | blocking fault |
| 160-11 | LF Steer Coil — Shorted to supply voltage | blocking fault |
| 160-12 | Steer Left Valve — Circuit shorted to V+ | blocking fault |
| 160-15 | Steer Left Valve — Circuit shorted to GND | blocking fault |
| 161-11 | RF Steer Coil — Shorted to supply voltage | blocking fault |
| 161-12 | Steer Right Valve — Circuit shorted to V+ | blocking fault |
| 161-15 | Steer Right Valve — Circuit shorted to GND | blocking fault |
| 169-12 | Primary Boom Extend / Retract Flow Valve — Circuit shorted to V+ | blocking fault |
| 169-15 | Primary Boom Extend / Retract Flow Valve — Circuit shorted to GND | blocking fault |
| 174-19 | Platform Rotate Toggle Switch — Stuck ON at power up. | warning / function limited |
| 177-12 | Engine Coolant Temperature — Value too high | blocking fault |
| 178-21 | Engine Warning Lamp — Fault | warning / function limited |
| 179-11 | Platform Recirculation Coil — Shorted to supply voltage | message |
| 179-21 | Engine Stop Lamp — Fault | blocking fault |
| 185-11 | ESTOP Source — Shorted to supply voltage | blocking fault |
| 186-11 | ESTOP Return — Shorted to supply voltage | blocking fault |
| 187-13 | TCON Bank power — Not detected | blocking fault |
| 188-13 | PCON Bank power — Not detected | blocking fault |
| 206-13 | TCON Bank Power Not Detected PCON Bank Power Not Detected | blocking fault |
| 240-12 | Turntable Sensor Power — P85PWR Short to B+ | blocking fault |
| 240-15 | Turntable Sensor Power — P85PWR Short to B- | blocking fault |
| 241-12 | Turntable Sensor Power — P109PWR is shorted to B+ | blocking fault |
| 241-15 | Turntable Sensor Power — P109PWR is shorted to B- | blocking fault |
| 242-12 | Sensor Power P26PWR — Circuit shorted to V+ | blocking fault |
| 242-15 | Sensor Power P26PWR — Circuit shorted to GND | blocking fault |
| 243-19 | Proximity Override Toggle Switch — Stuck ON at power up. | warning / function limited |
| 263-11 | Platform Level Loop Coil — Shorted to supply voltage | message |