Genie XC, HF and J boom lifts (S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF, S-60 J, S-80 J)
Genie error code 24-36 — Boom Angle Sensor — Internal check
Message on the display: Boom Angle Sensor — Internal check
Code 24-36 occurs in machines: Genie S-60 XC, S-80 XC, S-85 XC, S-80 HF, S-85 HF.
blocking fault
The Genie display shows code 24-36 with the message “Boom Angle Sensor — Internal check”. It is a blocking fault or a safety-related code: do not use the machine until the cause has been found and removed.
Effect on the machine: Boom Up, Extend and Turntable Rotate functions will not operate.
Possible causes
- The two internal sensing channels inside the Angle Sensor have registered a significant difference.
What you can do
Switch the machine off with the emergency stop and switch it on again. If the code comes back, do not use the machine and call service.
Solution from the manual
* Run the boom angle calibration process and verify fault is no longer active. * If fault persists, replace the sensor.
Source: Genie Service and Repair Manuals (Part No. 1316494, 1315679, 1288652, 1280490, 1285305, 1285307), Fault Codes section.
The descriptions are quoted from the manufacturer's service documentation and are for guidance only. Clearing codes, calibrations and repairs are carried out by a qualified service technician according to the manual for the specific serial number. A machine with an active blocking code must not be used until the cause has been removed.
Does code 24-36 not go away?
RK Rental services Genie lifts at our workshop or on site at the customer's premises (construction site, factory, warehouse). We read the code, remove the cause and select the parts by serial number.